FIRE
R M LD
FIRE
R M LD
Operator’s Manual
3
GAS LASER
Doc No. 16162 Rev A, GAS LASER Operator Manual
© 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
1
Laser Beam
Is Transmitt
ed
2
Plume Absorbs
Some Laser
3
Some Laser
Passes Through
6
Remaining Laser R
eturns t
o
Gas Laser and Is Measur
ed
4
Laser
Reflects Back
5
Plume Absorbs
Some Laser
Remote Detection for Increased Safety
The Gas Laser uses highly advanced technology to detect natural gas
plumes from a remote distance. This makes it safer to scan in areas that
may be difficult to reach such as busy roadways, yards with dogs, fenced off
areas, and other hard to access places.
Tunable Diode Laser Absorption Spectroscopy (TDLAS)
The Gas Laser employs Tunable Diode Laser Absorption Spectroscopy
(TDLAS) technology.
As the laser passes through the gas plume,
the methane absorbs a portion of the light, which the
instrument then detects. Based on the local meteorological
conditions, a given amount of gas escaping from the ground
will produce a plume that varies in size and uniformity of concentration
levels. The plume, by nature, is variable and dependent on the soil
conditions, temperature, wind, and leak rate.
Features
The Gas Laser includes many features which reduce costs and improve
usage. These advanced features include, but are not limited to:
- User Interface - highly optimized
for First Responders
- Internal Data Logging
- WiFi
- GPS
- Bluetooth BLE
- Color Camera
- Color Display
- Spotter laser
- Self Test
- Light Weight
- Rechargeable and Replaceable
Battery
- Dual Charger
- Ergonomic Housing
Overview
Proprietary Notice
The contents of this instruction manual are proprietary to Teledyne Gas Measurement Instruments Ltd. Reproduction
of this manual, in whole or in part, is prohibited without the express written consent of Teledyne Gas Measurement
Instruments Ltd.
Teledyne Gas Measurement Instruments Ltd. operates under a continual product improvement program and reserves
the right to make improvements and / or changes without prior notification.
This manual supersedes all previous manuals for this instrument.
Doc No. 16086 Rev A, Gas Laser Operator Manual | Date: October 21, 2021 | Copyright © 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
Operates under a
variety of field
conditions including:
- wide temperature range,
- light rain and fog.
Safe scanning from distances
of 100’ and 50’, using a
vehicle and tree for a shield
as an extra precaution.
Rugged design
stands up to normal
field use and operating
conditions.
Sensitivity or range
is not affected by
reasonable amounts
of dust on the
instrument’s window.
100’
50’
100’
50’
FIRE DEPT
Содержание GAS LASER