FIRE
R M LD
FIRE
R M LD
Operator’s Manual
12
GAS LASER
Doc No. 16162 Rev A, GAS LASER Operator Manual
© 2021 Teledyne Gas Measurement Instruments Ltd. All rights reserved.
1. Turn instrument OFF.
2. Unscrew the two captive
screws located on the bottom
of battery pack. Remove battery
from instrument.
3. Insert battery into the charger,
ensuring it is all the way down.
Optional: Fasten captive screws
into charger housing to prevent
battery from dislodging.
4. LED panel of charger illuminates
to show charging status of the
battery.
a. Green flashing = charging
b. Green solid = fully charged
c. No light = battery not present
or not connected properly
d. Red = fault
i. Position battery into the
other bay, if still red, then
try another battery.
ii. If the light is still red send
to repair or replace.
5. When fully charged in 2-3 hours,
power up the instrument to
verify the battery capacity on
the screen.
Charging Procedure
Remaining Battery Capacity
Remaining battery capacity
(in percent) is indicated in the
top right of the screen.
CAUTION
When storing the
instrument or battery
for more than a month:
- Charge battery to 40-50%
- Store at 60-70° F
Charge in ambient temperature above 50° F (10° C) to
obtain full battery capacity
a
b
c
d
a
b
c
d
Charging legend displayed on charger
White icon indicates
sufficient capacity
remaining
Red icon indicates low
capacity remaining/
time to charge
CAUTION: To prevent damage to
the battery or electrical circuits,
always plug the charger into a
surge-protected outlet.
WARNING: To reduce the risk of
ignition of a flammable or explosive
atmosphere, battery pack must be
removed, inserted and recharged
only in a location known to be
non-hazardous.
WARNING: Only use the Teledyne
supplied Gas Laser battery pack
charger to recharge the battery
pack. Use of any other charger
may cause severe damage to the
battery pack or electrical circuits.
Battery Charger is not part of the
hazardous safety certification.
AVERTISSEMENT
WARNING
AVERTISSEMENT : Pour réduire
le risque d’inflammation d’une
atmosphère inflammable ou
explosive, bloc-batteries doivent
être retirées, insérées et rechargées
uniquement dans un endroit réputé
non dangereux.
AVERTISSEMENT : Utiliser
uniquement le chargeur de
bloc-batterie Gas Laser fourni par
Teledyne pour recharger le bloc-
batterie. L’utilisation de tout autre
chargeur peut endommager
gravement le bloc-batterie ou
les circuits électriques. Le chargeur
de batterie ne fait pas partie de la
certification de sécurité dangere-
use.
Содержание GAS LASER