Teledyne Lecroy PCI Express 5.0 M.2 M-Key Interposer Скачать руководство пользователя страница 7

     Recording Traffic

 

We are continuously improving and releasing new products. For new interposers to operate optimally always check 
Teledyne LeCroy website for the latest version of the PCIe Protocol Analysis Software.
After you have set up the hardware and software, you can record traffic. 
For instructions on setting up and implementing a recording, please refer to the

 PCI Express Protocol Analysis Summit T5 

Gen5 Analyzer User Manual. 

Side Band Test Point Header J6207

Connector Pin Number

Signal Name

Connector Pin Number

Signal Name

1

Ground

17

VIO_CFG_HDR

2

No Connection

18

No Connection

3

CLK_32KHZ_SUSCLK_HDR

19

PERST#IN_HDR

4

No Connection

20

No Connection

5

GPIO_9_DAS_DSS_N_LED1_N_HDR

21

SMCLK_HDR

6

No Connection

22

No Connection

7

ALERT#IN_HDR

23

DEVSLP_DGND_HDR

8

No Connection

24

No Connection

9

PEDET_HDR

25

WAKE#_HTR

10

No Connection

26

No Connection

11

PWRDIS_HDR

27

CLKREQ#IN_HDR

12

No Connection

28

No Connection

13

PLN#_HDR

29

SMDAT_HDR

14

No Connection

30

No Connection

15

PLA_S3#_HDR

31

Ground

16

No Connection

7

Содержание PCI Express 5.0 M.2 M-Key Interposer

Страница 1: ...r PCIe x2 interface for SSDs WWAN or other non storage devices Socket 3 keyed as M is strictly for high performance storage offering x4 lanes of bandwidth in this form factor In some cases a B M keyed...

Страница 2: ...user to attach and secure the Teledyne LeCroy M 2 interposer cable on the host system which usually supports different M 2 card form factors Follow below instructions to install the extension bracket...

Страница 3: ...er 5 The view from the top side of the PCB is shown below The text Type 2280 is clearly visible Attaching the Cables to the Interposer 1 Once the cable assembly has been completed Method One or Method...

Страница 4: ...d which are 2230 2242 3042 2260 2280 and 22110 Move the M 2 standoff based on the DUT Type The standoff will be attached to 2280 location by default The DUT is secured by a thumbscrew on the top side...

Страница 5: ...lyzer and wait for it to be recognized by the application Note If prompted to update the firmware please do that before proceeding 9 Power on the host machine 10 Launch the Teledyne LeCroy software ap...

Страница 6: ...ut clocks can be HCSL LVPECL LVDS or any single ended standard input voltage amplitude not to exceed 800mV SW3 This switch connects the DUT power indication LEDs to the bus power In some systems with...

Страница 7: ...yzer User Manual Side Band Test Point Header J6207 Connector Pin Number Signal Name Connector Pin Number Signal Name 1 Ground 17 VIO_CFG_HDR 2 No Connection 18 No Connection 3 CLK_32KHZ_SUSCLK_HDR 19...

Страница 8: ...and MAUI oscilloscope software optional Signal Name PE222UIA X PE222UIA X 1PHY PE222UIA X 2PHY PE222UIA X 4PHY Pin Headers CLK_32KHZ SUSCLK X X X X DAS DSS LED_1 X X X X ALERT IN X X X X PEDET X X X X...

Страница 9: ...Capable Product Description Product Code High speed Data Signals 8 GHz differential probe with ProLink interface DH08 PL 13 GHz differential probe with ProLink interface DH13 PL 16 GHz differential pr...

Страница 10: ...Express pairs probe points as located on the left and right sides of the interposer Left Side View Right Side View Buffered Refclk Copy UMC Pin Header for Sideband Signals 1 8V Rail Voltage UMC 1 8V...

Страница 11: ...oscilloscope probes to the PCI express signals as shown in the figure below Connect each Oscilloscope Probe to the Required PCIe Bus Signal Interposer Ready for a Scope Analysis of Two Upstream and Do...

Страница 12: ...emarks of Teledyne LeCroy All other trademarks are property of their respective companies Changes Product specifications are subject to change without notice Teledyne LeCroy reserves the right to revi...

Отзывы: