Teledyne Lecroy PCI Express 5.0 M.2 M-Key Interposer Скачать руководство пользователя страница 5

   

Hardware Installation

To use this interposer:
1. Set the SW2 DIP switches to the desired clock selection.

Note:

 “HOST_CLK” should be the default setting unless you are using an external clock reference source.

2. Move the stand off from the default position to the position required by the DUT.
3. Install the M.2 SSD device under test (DUT) into the connector on the interposer as shown (will fit 30 mm, 42mm, 

60mm, 80mm and 110mm).

4. Connect the Summit Analyzer to the interposer using the high speed serial cables (If using Summit T54 use Gen5 Y 

cable PE028UCA-X. If using Summit T54 with Gen5 Phy use Gen5 straight cable PE027UCA-X).

5. Connect the analyzer to a host machine using the USB port on the front panel of the Summit analyzer.
6. If not already done, install the PCIe Protocol Analysis on the host machine.
7. Connect 12V DC using the AC adapter supplied with the interposer. (Make sure that the AC adapter is powered on).
8. Power on the Analyzer and wait for it to be recognized by the application. 

Note

: If prompted to update the firmware 

please do that before proceeding.

9. Power on the host machine.
10. Launch the Teledyne LeCroy software application to monitor, record and view PCI Express traffic passing through the 

M.2 Interposer.

11. Power on the system under test.

Note:

 Step 8, 9, and 10 are needed in this order for “Power On

 traces.

Note:

 Use the link width control button SW1 to match the minimum physical lane width of the host and device.

PCI Express Gen5 M.2 MKey Interposer CrossSync Phy Interposer Interconnection Overview

Keyed paddle board 
inserts in M.2 connector

12 V DC from power supply

Upstream connection to oscilloscope

Reference clock probe connections

Summit T54 Gen5 Phy

Power rail probe connections

External clock inputs

Device under test (DUT) Compatible with

30x30, 30x42, 30x60, 30x80, 30x110 and
22x30, 22x42, 22x60, 22x80, 22x110

SSD carrier board

Sideband signal connections

Downstream connection to oscilloscope

PE028UCA-X Y Cable (Use with T54 Expanded Mode or Summit T516)
PE027UCA-X straight cable (Use with Summit T54 or Summit T516 MultiPort Mode)

5

Содержание PCI Express 5.0 M.2 M-Key Interposer

Страница 1: ...r PCIe x2 interface for SSDs WWAN or other non storage devices Socket 3 keyed as M is strictly for high performance storage offering x4 lanes of bandwidth in this form factor In some cases a B M keyed...

Страница 2: ...user to attach and secure the Teledyne LeCroy M 2 interposer cable on the host system which usually supports different M 2 card form factors Follow below instructions to install the extension bracket...

Страница 3: ...er 5 The view from the top side of the PCB is shown below The text Type 2280 is clearly visible Attaching the Cables to the Interposer 1 Once the cable assembly has been completed Method One or Method...

Страница 4: ...d which are 2230 2242 3042 2260 2280 and 22110 Move the M 2 standoff based on the DUT Type The standoff will be attached to 2280 location by default The DUT is secured by a thumbscrew on the top side...

Страница 5: ...lyzer and wait for it to be recognized by the application Note If prompted to update the firmware please do that before proceeding 9 Power on the host machine 10 Launch the Teledyne LeCroy software ap...

Страница 6: ...ut clocks can be HCSL LVPECL LVDS or any single ended standard input voltage amplitude not to exceed 800mV SW3 This switch connects the DUT power indication LEDs to the bus power In some systems with...

Страница 7: ...yzer User Manual Side Band Test Point Header J6207 Connector Pin Number Signal Name Connector Pin Number Signal Name 1 Ground 17 VIO_CFG_HDR 2 No Connection 18 No Connection 3 CLK_32KHZ_SUSCLK_HDR 19...

Страница 8: ...and MAUI oscilloscope software optional Signal Name PE222UIA X PE222UIA X 1PHY PE222UIA X 2PHY PE222UIA X 4PHY Pin Headers CLK_32KHZ SUSCLK X X X X DAS DSS LED_1 X X X X ALERT IN X X X X PEDET X X X X...

Страница 9: ...Capable Product Description Product Code High speed Data Signals 8 GHz differential probe with ProLink interface DH08 PL 13 GHz differential probe with ProLink interface DH13 PL 16 GHz differential pr...

Страница 10: ...Express pairs probe points as located on the left and right sides of the interposer Left Side View Right Side View Buffered Refclk Copy UMC Pin Header for Sideband Signals 1 8V Rail Voltage UMC 1 8V...

Страница 11: ...oscilloscope probes to the PCI express signals as shown in the figure below Connect each Oscilloscope Probe to the Required PCIe Bus Signal Interposer Ready for a Scope Analysis of Two Upstream and Do...

Страница 12: ...emarks of Teledyne LeCroy All other trademarks are property of their respective companies Changes Product specifications are subject to change without notice Teledyne LeCroy reserves the right to revi...

Отзывы: