Teledyne Lecroy PCI Express 5.0 M.2 M-Key Interposer Скачать руководство пользователя страница 2

PCI Express 5.0 M.2 M-Key Interposer CrossSync 
PHY Capable Carrier board

Connector cable assembly 18 inches for 
connection to host slot

DC Power Adapter (+12V @ 3 Amps)

Depending on configuration: SMA to BNC 3ft 
Cable 

Extension bracket kit (metal brackets with clip) 
supporting M.2 devices of 60, 80 and 110mm 
devices (depending on purchased configuration 
two more bracket sizes 30 and 42mm included)

Thumbscrew and standoff

User Manual and Quick Start Guide (this 
document)

2

     Interposer Cable Assembly Installation

If required, install a different extension bracket to the small PCB at the end of the 18" interposer cable. The extension 
brackets are provided to allow the user to attach and secure the Teledyne LeCroy M.2 interposer cable on the host system 
which usually supports different M.2 card form factors. Follow below instructions to install the extension brackets that will fit 
your application.

Cable Assembly for Screw Attachment with 42mm PCB Configuration

The cable comes already with the Type 2260 bracket extension installed. To install a different bracket follow below 
procedure. The Teledyne LeCroy M.2 Interposer Extension Bracket Kit contains the items listed below. The items are 
shown in the figure below.

Type 22110 Extension bracket 

Type 2280 Extension bracket

Type 2260 Extension bracket.

Screws to attach the Extension bracket to the interposer Cable Assembly

M2 Interposer Extension Bracket Kit 

3

     Components

The Teledyne LeCroy 5.0 M.2 M-Key Interposer CrossSync PHY Capable kit has the following components:

Содержание PCI Express 5.0 M.2 M-Key Interposer

Страница 1: ...r PCIe x2 interface for SSDs WWAN or other non storage devices Socket 3 keyed as M is strictly for high performance storage offering x4 lanes of bandwidth in this form factor In some cases a B M keyed...

Страница 2: ...user to attach and secure the Teledyne LeCroy M 2 interposer cable on the host system which usually supports different M 2 card form factors Follow below instructions to install the extension bracket...

Страница 3: ...er 5 The view from the top side of the PCB is shown below The text Type 2280 is clearly visible Attaching the Cables to the Interposer 1 Once the cable assembly has been completed Method One or Method...

Страница 4: ...d which are 2230 2242 3042 2260 2280 and 22110 Move the M 2 standoff based on the DUT Type The standoff will be attached to 2280 location by default The DUT is secured by a thumbscrew on the top side...

Страница 5: ...lyzer and wait for it to be recognized by the application Note If prompted to update the firmware please do that before proceeding 9 Power on the host machine 10 Launch the Teledyne LeCroy software ap...

Страница 6: ...ut clocks can be HCSL LVPECL LVDS or any single ended standard input voltage amplitude not to exceed 800mV SW3 This switch connects the DUT power indication LEDs to the bus power In some systems with...

Страница 7: ...yzer User Manual Side Band Test Point Header J6207 Connector Pin Number Signal Name Connector Pin Number Signal Name 1 Ground 17 VIO_CFG_HDR 2 No Connection 18 No Connection 3 CLK_32KHZ_SUSCLK_HDR 19...

Страница 8: ...and MAUI oscilloscope software optional Signal Name PE222UIA X PE222UIA X 1PHY PE222UIA X 2PHY PE222UIA X 4PHY Pin Headers CLK_32KHZ SUSCLK X X X X DAS DSS LED_1 X X X X ALERT IN X X X X PEDET X X X X...

Страница 9: ...Capable Product Description Product Code High speed Data Signals 8 GHz differential probe with ProLink interface DH08 PL 13 GHz differential probe with ProLink interface DH13 PL 16 GHz differential pr...

Страница 10: ...Express pairs probe points as located on the left and right sides of the interposer Left Side View Right Side View Buffered Refclk Copy UMC Pin Header for Sideband Signals 1 8V Rail Voltage UMC 1 8V...

Страница 11: ...oscilloscope probes to the PCI express signals as shown in the figure below Connect each Oscilloscope Probe to the Required PCIe Bus Signal Interposer Ready for a Scope Analysis of Two Upstream and Do...

Страница 12: ...emarks of Teledyne LeCroy All other trademarks are property of their respective companies Changes Product specifications are subject to change without notice Teledyne LeCroy reserves the right to revi...

Отзывы: