Page 1-6
IFC stranded cable from the splice vault is secured at either rear corner of the LCX Splice Panel
by an optional cable clamp. (A single clamp comes with two rubber bushings to fit either a 12- or
24-fiber IFC riser/plenum cable.) The following illustration shows a clamp holding an IFC cable
installed on the rear rack flange near the entry/exit of an LCX 1RU Splice Panel. The
interconnection cables enter the tray at one of the other corners of the splice tray.
Figure 7 - 1RU Cable Clamp Fits 12 to 24 Fiber IFC
Tie-Down for Cable Ties*
Tie-Down for Cable Ties*
From
IFC
To Network
Elements
* Use either lacing or cable ties to secure cable subunit, flexible tubing, and/or sheathing.
Figure 6 - 1RU Splice Tray - Fiber Routing
C a ble C la m p
2 4-F ib e r IF C
N e tw o rk C a ble
Leave sufficient
slack to a llo w d raw e r
to open.