1.2 DSX-3 Specifications         

Electrical Interface:

Specifications:

Insertion Loss

 < 1.00 dB at DS3/E3 signal rates

Monitor Level

21 dB + 1.5 dB below signal level

Return Loss

< -26 dB at DS3/E3, STS-1 signal rates

< -26 dB at E3 signal rate of 17.184 Mhz

< -15 dB at STS-3/STM-1 signal rates

Contact Resistance

< 0.01

Ω

Characteristic Impedance

75

Ω

Tracer Lamp LED

Draws 9mA at -48Vdc

Mechanical Interface:

Specifications:

Jack Insertion Force

10 lbs maximum, 4.1 lbs. minimum

 

Jack Withdrawal Force 

7 lbs. maximum, 3.8 lbs. minimum

Jack Life

Minimum 10,000 insertion/withdrawal cycles

Environment:

Specifications:

Thermal 

Ambient 

Limits

-55°C to 85°C, non-operating

-5°C to +55°C, operating

Thermal Shock

per MIL-STD-202, methods 107D

Humidity

0% to 95%, noncondensing, operating and non-operating

Содержание DSX-3

Страница 1: ...BCS 4R DSX 3 Connectivity System Models 010 8332 0410 010 8332 0401 010 8324 0410 and 010 8324 0401 User Manual ...

Страница 2: ...rs This document and the products described herein are subject to change without notice About Telect Telect offers complete solutions for physical layer connectivity power equipment housing and other network infrastructure equipment From outside plant and central office to inside the home Telect draws on more than 25 years of experience to deliver leading edge product and service solutions Telect ...

Страница 3: ...ance Activities 6 1 1 8 Features Capabilities Capacities Benefits 7 1 1 9 Compliance 7 1 2 DSX 3 Specifications 8 Chapter 2 Installation 9 2 1 Installation Considerations 9 2 1 1 Location and Space 9 2 1 2 Computer Floor Issues 10 2 1 3 Required Tools and Equipment 10 2 2 Inspection 10 2 3 Installation 11 Chapter 3 Electrical Operation 17 3 1 Power 17 3 1 1 Tracer Lamps TL 18 3 1 2 Monitor Ports 1...

Страница 4: ... 5 Figure 6 Rack 9 Figure 7 Mounting Chassis to Rack 11 Figure 8 Routing Power 12 Figure 9 Grounding the Chassis 13 Figure 10 BNC Insertion Tool 13 Figure 11 Connections 14 Figure 12 Rear Cross Connect Cables with Tracer Wire 15 Figure 13 Power from Distribution Panel to Front Tracer Lamp 17 Figure 14 Tracer Lamp Operation 18 Figure 15 Schematic Drawing of Cross Connection 19 Figure 16 Rear Cross ...

Страница 5: ...hassis accommodates up to 32 of Telect s highly reliable 6 port BCS 4R DSX 3 modules Each low cost DSX 3 module features BNC and Mini WECO connectors for cross connecting patching testing and bi directional monitoring of network element circuits Panels are available fully configured and loaded with DSX 3 modules helping to simplify purchasing and installation Options include 24 termination 19 and ...

Страница 6: ...Telect Inc USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 139256 A0 Page 1 2 Figure 2 Rear View of Fully Loaded Chassis BCS 4R BCS 4R ...

Страница 7: ...port or 4 port modules See the following table for part numbers Table 1 Fully loaded 19 and 23 DSX 3 panels Chassis Module Part Number 19 24 position 6 port 010 8324 0410 19 24 position 4 port 010 8324 0401 23 32 position 6 port 010 8332 0410 23 32 position 4 port 010 8332 0401 R2 R1 LED ASSEMBLY TL R2 R1 MON OUT IN MON O OX IX I BATT A TL RTN A RTN A TL BATT A LED ASSEMBLY TL MON IN OUT MON R2 R1...

Страница 8: ...ween DSX 3 Modules should be 27 ft or less Figure 4 Cross connect Inputs The four ports on the front of the module are Mini WECO connectors for temporary Input I and Output O patch cords 734A or 735A cables from to a standby DSX 3 circuit and for temporary Monitor M patch cords The I and O patch connections are intrusive highly reliable make and break connections that break disconnect the cross co...

Страница 9: ... positions respectively for BCS 4R DSX 3 modules Each chassis includes a power backplane to feed 48Vdc tracer lamp power to the DSX 3 modules Each chassis comes with cable management ring assemblies that attach to the rear of the rack and flipout designation cards that attach to the mounting brackets on the front of the rack Designation cards are not shown in the following illustration All mountin...

Страница 10: ... substitute equipment for verification Digital line patch cords at the DSX can immediately restore any out of service facility whether caused by a cable cut malfunctioning equipment etc Rather than using jacks located at the individual units manual restoration patching can be done at a centralized location at the DSX When the equipment or cable is repaired or routing for preventive maintenance is ...

Страница 11: ...e Monitor Mini WECO on the front bi directional monitoring tracer lamps for identifying cross connections during troubleshooting fully configured panels that streamline ordering and accelerate deployment high density 24 terminations in a 19 chassis 32 terminations in a 23 chassis space savings Each panel just 4 in height essential functionality 6 port mini WECO modules enable bi directional monito...

Страница 12: ...gnal rate of 17 184 Mhz 15 dB at STS 3 STM 1 signal rates Contact Resistance 0 01Ω Characteristic Impedance 75Ω Tracer Lamp LED Draws 9mA at 48Vdc Mechanical Interface Specifications Jack Insertion Force 10 lbs maximum 4 1 lbs minimum Jack Withdrawal Force 7 lbs maximum 3 8 lbs minimum Jack Life Minimum 10 000 insertion withdrawal cycles Environment Specifications Thermal Ambient Limits 55 C to 85...

Страница 13: ... presume you have verified that the Telect equipment being installed is compatible with the rest of the system including power ground circuit protection signal characteristics equipment from other vendors and local codes or ordinances ALERT Use this equipment in a RESTRICTED ACCESS LOCATION ONLY 2 1 1 Location and Space The BCS 4R chassis mount in standard 19 in or 23 in WECO spaced or EIA spaced ...

Страница 14: ...structing BNC connector ends Die sets required depending on cable BNC insertion tool Telect PN 097197 2 2 Inspection Compare the contents of the shipping container with the packing list Call Telect or your distributor if you are missing anything Telect is not liable for shipping damage If the shipping container is damaged keep it for the carrier s inspection Notify the carrier and call Telect s Cu...

Страница 15: ...t rings on the rear rack flange using the hardware provided 3 Repeat Steps 1 and 2 to install all BCS 4R chassis before installing power and I O cables to any BCS 4R chassis in the rack 4 For BCS 4R chassis that require power route power from the power distribution panel to con nectors on the rear of BCS 4R chassis Use wire in the 10 22 AWG range Strip away about 3 8 in 10 mm of insulation and the...

Страница 16: ...Telect Inc USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 139256 A0 Page 2 12 Figure 8 Routing Power ...

Страница 17: ...re 9 Grounding the Chassis 6 Connect I O cables to the rear of the chassis as shown in the following illustration In general For network I O cables originating overhead start with the lowest BCS 4R chassis in the rack and work up For network I O cables originating from below start with the highest chassis in the rack and work down NE I O cables connect to the lower I O connectors on the chassis Us...

Страница 18: ...y along the lower tie down bar and tie down lances loops at the rear of the chassis 8 Insert cross connecting cables to upper two connectors labeled IX and OX on DSX cards 9 If applicable connect tracer wire to the port above the tracer LED as shown 10 Use cable ties along the upper tie down bar to restrain the X connect cables Figure 11 Connections ...

Страница 19: ...Telect Inc USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 139256 A0 Page 2 15 Figure 12 Rear Cross Connect Cables with Tracer Wire ...

Страница 20: ...Telect Inc USA 1 509 926 6000 Mexico 52 33 3836 37 52 www telect com 2010 Telect Inc All Rights Reserved 139256 A0 Page 2 16 This page intentionally left blank ...

Страница 21: ...acer lamps TL LED on the front of DSX and repeater cards and LEDs on the rear of the chassis Power connects to the Power Alarm Terminal Strip on the back of each DSX chassis The strip terminates a bus on the chassis backplane all DSX card connectors on the backplane tap into the signal lines of this bus Power for the rear TLs passes from the bus on the backplane through the DSX card to a small PCB...

Страница 22: ...r MON Test equipment may be applied without interrupting service The three port card has a monitor for the OUT signal only 3 2 DSX Cross Connections Do not make rear cross connections using cables longer than 27 ft unless using a repeater card Do not make front patch connections longer than 20 feet 3 2 1 Backplane Cross Connections To cross connect two network elements use approved coax cable and ...

Страница 23: ...tic Drawing of Cross Connection Figure 16 Rear Cross Connect Cables with Tracer Wire X X X IN X IN I I I I R1 R1 I I X X REAR REAR MON MON FRONT FRONT TL TL X OUT X OUT R1 75 R1 75 R2 768 R2 768 RTN A RTN A BATT A BATT A O O O O MON MON R2 R2 R1 R1 R2 R2 LED ASSEMBLY LED ASSEMBLY TL TL O O Network Element 1 Network Element 2 T R ACE RW IR E ...

Страница 24: ...patches to temporarily re route signals Patches with jacks labeled O OX I IX are intrusive and interrupt service Use 734A or 735A cable Patch only to cards less than 20 feet away Remove temporary patches in accordance with office procedures after permanent backplane cross connections have been made Figure 17 Temporary Front Cross Connect Using Patch Cables DSX Cards ...

Страница 25: ...connect points on every card 4 3 Replacing the Tracer Lamp LED Pull the LED assembly and plastic holder straight out If LED polarization is not correct the replacement will not work Orient the new LED in the plastic holder the same as the original The shape of the LED holder slot in the DSX module is keyed for proper LED insertion 4 4 Service 4 4 1 In Warranty Service Contact your Telect equipment...

Страница 26: ...e returning equipment Call a Customer Service Representative for help getting these forms The processing fee guarantees a repair estimate and is credited against actual material and labor costs 4 5 Repacking For Shipment Telect is not liable for shipping damage 1 Tag the equipment showing owner s name address and telephone number together with a detailed description of the problem 2 Use the origin...

Отзывы: