Model 458-CC-16/458-CM (16-Slot Chassis & Control Module) Rev I 

Page 35   

 

 

Use the menu on the left side of the screen to navigate. 

 
Local Port Setting 

To ensure the local port setting matches the one entered when configuring the virtual COM port, do 
the following: 
 

1.  Click on 

Connection

 under the Channel 1 section. The Connection Settings screen appears.  

Содержание 458-CC-16

Страница 1: ...Model 458 CC 16 458 CM 16 Slot Chassis Control Module Rev I Date of Publication 02 25 2019 Line Modules Not Included Results You Can Count On...

Страница 2: ...e Modules it becomes a 128 channel local loop simulator The 458 CM Control Module interfaces with a PC or terminal via IEEE 488 or RS 232 Ethernet to control loop length settings or the 458 CC 16 458...

Страница 3: ...riod Warranty repairs will be performed at the point of manufacture Equipment approved for return for warranty service shall be returned F O B TELEBYTE factory and will be redelivered by TELEBYTE frei...

Страница 4: ...reduced charge will be billed to cover handling testing and packaging Whether in or out of warranty a Return Material Authorization number RMA is required and may be obtained by Calling customer servi...

Страница 5: ...ions Commands 14 Enabling Ethernet Connectivity 14 Before You Begin 15 Installing IP Address Assignment Software 15 Configure Virtual Com Port on Remote PC 22 Install Software 22 Create Virtual COM Po...

Страница 6: ...able through the RS 232 port The Model 458 CC 16 458 CM is used with our advanced 458 Line Modules that simulate several cable types and offer the bandwidth requirements for today s xDSL technologies...

Страница 7: ...figured for IEEE 488 the 458 CM can be operated from an IEEE Controller such as a PC equipped with an IEEE interface board In RS 232 mode the unit can be connected to any RS 232 device e g a terminal...

Страница 8: ...458 Line Module are via a backplane The backplane will pass power and the signals to control the length of each card The RJ 45 connectors used to connect to the unit to be tested are mounted directly...

Страница 9: ...ication parameters Indicators Backlit LCD display of line length and set up parameters Power 88 to 264 VAC 50 or 60 Hz Size 7U 19 in W x 22 in D x 12 22 in H 482 6 mm W x 558 8 mm D x 310 4 mm H Envir...

Страница 10: ...n the PC or controller Pin 3 on the Model 458 CM connects to the TRANSMIT DATA pin in the Communications Port Connector on the PC or controller Pin 5 on the Model 458 CM connects to the GROUND pin in...

Страница 11: ...rd lengths English Metric mode and Echo enable disable are maintained during power off in both RS 232 and IEEE modes Manual control is enabled at power on id Identify model no and rev Read model no an...

Страница 12: ...is open O connect CO only CPE is open Z open both CO and CPE ends Example SL 01 1 2000 N sets channel 1 to 2000 ft for a line module in slot 1 The connect mode may be used to create an open loop condi...

Страница 13: ...l Example rl all reports the lengths of all channels on all boards Read the serial number of one line module command rs LM Read the serial numbers of all cards command rs all Responses to SL Set Lengt...

Страница 14: ...peration Figure 3 IEEE 24 pin Connector Connect a standard IEEE cable from the Model 458 CM to the IEEE General Purpose Interface Bus controller User Command Interface The Model 458 CM is intended to...

Страница 15: ...power on manual disable Disable manual control Disable manual setting of lengths or configuration manual enable Enable manual control Enable manual setting of lengths or configuration lasterror Read...

Страница 16: ...alue of the bits following the command SRE Used to read the Enabling Bits in the Status Register STB Reads the Status Register ESExx Enables Event Status Bits as defined by the numerical value of the...

Страница 17: ...O is open O connect CO only CPE is open Z open both CO and CPE ends Example setcard length 01 1 2000 n sets channel 1 of the line module in slot 1 to 2000 ft Responses to SC SetCard Command Command va...

Страница 18: ...boards 1 2 and 3 to 2000 ft Set all channels on one board command setcard length LM a LE C Example setcard length 1 a 2000 n sets all channels on the board in slot 1 to 2000 ft Read Length command rea...

Страница 19: ...on to control the Model 458 CM This is made possible by a Lantronix XPort transceiver installed in the unit A one time set up must be performed to assign an IP address to the transceiver and configure...

Страница 20: ...select Support Software option It is then copied to the remote PC and expanded After installation it is used to assign an IP address to the XPort Obtain the IP address and subnet mask for the XPort fr...

Страница 21: ...Model 458 CC 16 458 CM 16 Slot Chassis Control Module Rev I Page 16 5 Click Install 6 Click Next The Select Installation Folder screen is shown...

Страница 22: ...e default folder information or click Browse to find and select a new location The Confirm Installation screen is displayed 8 Click Next to begin installation The progress screen is shown followed by...

Страница 23: ...t Programs Lantronix DeviceInstaller DeviceInstaller b For Windows XP Click Start All Programs Lantronix DeviceInstaller DeviceInstaller If the remote PC has more than one network adapter a prompt app...

Страница 24: ...t displayed in the left panel the Xport device associated with the 458 chassis may not be displayed in the right panel If that is the case click Tools Options Local Area Connection should checked Unch...

Страница 25: ...age 20 4 If the default IP address is not correct click the Assign IP icon on the top left of the DeviceInstaller control screen 5 If the Device Identification screen is displayed Enter the MAC addres...

Страница 26: ...Slot Chassis Control Module Rev I Page 21 6 The Assign Method screen is displayed Select the Assign a specific IP address option and click Next The IP Settings screen is displayed 7 Enter the IP addre...

Страница 27: ...Completed Successfully Click Finish Note the Device Installer control window now reflects the new IP address Configure Virtual Com Port on Remote PC The virtual COM port software Lantronix Com Port R...

Страница 28: ...Control Module Rev I Page 23 2 Click Install The Welcome screen is displayed 3 Click Next The installation progress is shown and you are returned to the Welcome screen again Click Next The Choose Des...

Страница 29: ...efault location and install the files or click Browse to navigate to the desired location A Setup Status screen is displayed indicating the progress of the installation When complete the InstallShield...

Страница 30: ...8 CC 16 458 CM 16 Slot Chassis Control Module Rev I Page 25 Create Virtual COM Port 1 Launch the Lantronix Redirector program Start All Programs Lantronix CPR 4 3 CPR Manager 2 The CPR Manager window...

Страница 31: ...move on the upper left of the screen The Com Setup screen is displayed 4 Select an available COM port Select addition Com ports for each 458 chassis on the local area network These COM ports can be us...

Страница 32: ...Model 458 CC 16 458 CM 16 Slot Chassis Control Module Rev I Page 27 5 In the Com Ports panel on the left click on the New com port to highlight it Select Search For Devices...

Страница 33: ...Device List panel along the bottom Double click on the device in order to assign it to the highlighted com port The Host IP address and TCP Port will automatically be populated in the Settings panel D...

Страница 34: ...Slot Chassis Control Module Rev I Page 29 9 There will be two Hardware installation warning windows These warnings are due to the new virtual com ports added Click Continue Anyway in both prompts to...

Страница 35: ...to section 4 0 RS 232 Ethernet Controls for a list of the RS 232 commands available to control the Model 458 3SLB Only one connection at a time is allowed If you receive a message in the terminal emu...

Страница 36: ...Slot Chassis Control Module Rev I Page 31 3 In the Connection Description field enter a name for the connection Click OK 4 In the Connect using filed select the virtual Com port which was created and...

Страница 37: ...458 CC 16 458 CM 16 Slot Chassis Control Module Rev I Page 32 5 The Port Settings should be Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow control None Click OK to establish the connec...

Страница 38: ...local area network a virtual Com port should be configured and assigned to each device as described above These devices can then be controlled through HyperTerminal or equivalent software independent...

Страница 39: ...Address field Please note the address in this field may be entered directly into a Web browser for direct access without using the DeviceInstaller program 3 The Password screen is shown If required e...

Страница 40: ...the menu on the left side of the screen to navigate Local Port Setting To ensure the local port setting matches the one entered when configuring the virtual COM port do the following 1 Click on Connec...

Страница 41: ...he settings are being saved and a progress bar is shown When the update to the transceiver is complete the Device Server Configuration Manager screen is displayed Selecting Setting Baud Rate The Baud...

Страница 42: ...ppears 2 Select the desired Baud Rate from the Port Settings section Click OK The message Done is displayed to the right of the OK button at the bottom of the screen When this message disappears click...

Страница 43: ...e Run window is shown 2 Enter arp s IP address MAC address Example arp s 172 16 21 241 00 20 4A 95 B0 E6 3 Enter telnet IP address 1 Example telnet 172 16 21 241 1 4 Enter telnet IP address 9999 Examp...

Страница 44: ...Note Values shown in brackets are the current values for the setting 7 In the Change Setup menu type 0 to configure the server Press Enter key 8 Enter the IP address in the standard format e g 172 16...

Страница 45: ...w controlling the unit remotely via telnet This is indicated as Telnet Com Port Cntrl Enabled Note When the DisConnMode is set to 40 there may be odd characters displayed if using remote terminal soft...

Страница 46: ...tric mode and Echo enable disable are maintained during power off in both RS 232 and IEEE modes Manual control is enabled at power on id Identify model no and rev Read model no and software revision c...

Страница 47: ...Configure 488 Where ADD 1 2 29 30 No leading zeroes used Set Length command sl LM H LE C Where LM Module slot number 01 16 H Channel number 1 8 LE Length in feet C Connect mode N connect both CO and C...

Страница 48: ...1 2 and 3 to 2000 ft Set all channels on one board command sl LM a LE C Example sl 01 a 2000 n sets all channels on the board in slot 1 to 2000 ft Read Length command rl LM H Example rl 01 1 reports t...

Страница 49: ...Model 458 CC 16 458 CM 16 Slot Chassis Control Module Rev I Page 44 Read the serial number of one line module command rs LM Read the serial numbers of all cards command rs all...

Страница 50: ...Control Module Rev I Page 45 6 0 Keypad Controls The sample screen above shows how the keypad controls are used The LCD displays the slot channel length and configuration type In this example the leng...

Страница 51: ...channel number 2 Down Arrow decrease slot channel number 3 Left Arrow decrease length 4 Right Arrow increase length 5 C Config switch used to access second menu for communications settings such as RS2...

Отзывы: