Model 458-CC-16/458-CM (16-Slot Chassis & Control Module) Rev I
Page 6
User Command Interface
ASCII command set compliant with IEEE 488.2 and in Hex ASCII two-character bytes per 488
bus data byte.
RS-232 - LF, Baud rate 300 to 19200, commands use terminating character (Carriage Return),
eight Data Bits, one Stop Bit.
RS-232 Mode Command List
All Set card lengths, English/Metric mode and Echo enable/disable are maintained
during power off in both RS-232 and IEEE modes. Manual control is enabled at power
on.
id
Identify model no. and rev.
Read model no. and software revision code
re
Read last error
Read description of last error
ee
Echo enable
Echo all inputs and format output for terminal display
ed
Echo disable
Inputs not echoed and format output for user control program
h
Help RS232 command list
Read RS232 command list
cs:BR
Configure serial
Where BR = 300, 600, 1200, 2400, 4800, 9600 or 19200