Slow blinking
Detection error (Strength: High or Low).
1.3 Configuration Commands
This chapter describes the power sourcing equipment (PSE) configuration commands and is divided into the follow-
ing sections:
• Viewing the PSE configuration prompt.
• PSE configuration commands.
1.4 Viewing the PSE configuration prompt
To access the configuration environment, do the following:
(1)
At the GESTCON (*) prompt, enter PROCESS 4 (or P 4) or CONFIG.
(2)
At the configuration prompt (Config>), enter NETWORK <interface_name> (interface_name is the name of
the Ethernet interface on which the PSE functionality can be used).
(3)
To set specific POE parameters, use the available commands from the PSE configuration menu described in
this chapter. To access the menu corresponding to the specific parameters, enter the POWER-
SOURCING-EQUIPMENT command once inside the interface configuration.
*config
Config>net ethernet0/0
-- Ethernet Interface User Configuration –
ethernet0/0 config>?
description
Enter interface description
input-buffers
Number of rx buffers
ip
Interface Internet Protocol config commands
ip-encapsulation
IP transport mode in the ethernet frame
list
Displays the current configuration
llc
Displays the LLC configuration prompt
mac-address
Adopt locally administered addresses
no
power-sourcing-equipment
Access to the Power Sourcing Equipment configuration
repeater
Access to the repeater configuration
shutdown
Change state to administratively down
update
Update a level indicator
exit
ethernet0/0 config>power-sourcing-equipment
-- Power Sourcing Equipment configuration --
ethernet0/0 PSE config>
Certain commands are common to all device interfaces. These commands are described in the manual on common
configuration interfaces (Teldat-Dm772-I Common Configuration Interfaces).
1.5 Configuring PSE
This section describes the PSE configuration commands.
Command
Function
? (HELP)
Allows you to view the available commands, as well as the available options within
a command.
AVAILABLE-POWER
Configures the available power value.
DEFAULT-
PORT-CONSUMPTION
Configures the default power consumption value for each connected port.
ENABLE
Enables power sourcing equipment.
LIST
Lists the interface options configuration.
NO
Sets the default of a particular option.
PORT
Configures each port individually.
TRACE
Enables tracing.
Teldat SA
1 Configuration
PoE Power over Ethernet
3