Ports Status
Status of each port. The list of available states is as follows:
Port Status
Adm. auto
The port mode has been set as
auto
with the
mode-port auto
monitoring com-
mand.
Adm. disabled
The port has been disabled with the
disable-port
monitoring command. This com-
mand overrides the current configuration.
Adm. force <n> mW
The port mode has been forced to deliver the specified power. This has been en-
abled with the
mode-port force-power
monitoring command.
Detect Unknown
The port is in
auto
mode. Detection has not completed.
Detect Short Circuit
The port is in
auto
mode. A short circuit was detected during the detection pro-
cess.
Detect Signature Resistance
Low
The port is in
auto
mode. The detection process has revealed that the resistance
presented by the device is below that specified in the IEEE.802.3af norm (below
15K).
Detect Signature Resistance
High
The port is in
auto
mode. The detection process has revealed that the resistance
presented by the device is above that specified in the IEEE.802.3af norm (above
33K).
Detect Good
The port is in
auto
mode. The device class has been correctly detected as shown.
Detect Open Circuit
The port is in
auto
mode. No device has been detected.
Disabled
The port is disabled and will not deliver power.
Power forced, applied <n> mW
Power is unconditionally applied to the port as shown, except when a short circuit
is detected.
Unavailable
The port cannot be managed because the device is unavailable. This can happen
when there is no power.
The list of detected classes is as follows:
Class
0
Power delivered by default: 15400 mW.
Default class for devices that do not implement detection.
1
“Low Power PD” devices
Power delivered by default: 4000 mW.
2
“Medium Power PD” devices
Power delivered by default: 7000 mW.
3
“High or Full Power PD” devices
Power delivered by default: 15400 mW.
4
Reserved. Power is delivered as for class 0.
5
Reserved. Power is delivered as for class 0.
2.3.5 MODE-PORT
Changes the operating mode of the ports.
Syntax:
ethernet0/0 PSE+mode-port <port number> <mode> <assigned power>
<port number>
<5..8>
Value in the specified range
all
All ports
<mode>
auto
auto mode
default
set default mode
force-power
force power
<power assigned>
<4500..15400>
milliWatts
Teldat SA
2 Monitoring
PoE Power over Ethernet
11