Example 1:
To change the operating mode of port 5 to power forced mode and assign it 7600mw:
ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power
= 7600 mW
POE output power per port
= As requested
Ports Status
Port 5: Detect Signature Resistance Low
Port 6: Power forced, applied 7600 mW
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit
ethernet0/0 PSE+mode-port 5 force-power 7600
Port 5 new mode: force power, with 7600 milliwatts assigned
ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power
= 15200 mW
POE output power per port
= As requested
Ports Status
Port 5: [Adm. force 7600 mW] Power forced, applied 7600 mW
Port 6: Power forced, applied 7600 mW
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit
ethernet0/0 PSE+
Example 2:
To change the operating mode of port 6 to automatic mode:
ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power
= 15200 mW
POE output power per port
= As requested
Ports Status
Port 5: [Adm. force 7600 mW] Power forced, applied 7600 mW
Port 6: Power forced, applied 7600 mW
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit
ethernet0/0 PSE+mode-port 6 auto
Port 6 new mode: auto
ethernet0/0 PSE+list-status
POE cards: - POE card 1 (Ports 5-8)
Available PSE output power = 120000 mW
Minimum PSE output power
= 14600 mW
POE output power per port
= As requested
Ports Status
Port 5: [Adm. force 7600 mW] Power forced, applied 7600 mW
Port 6: [Adm. auto] Detect Good, Class2, requested 7000 mW, applied 7000 mW
Port 7: Detect Open Circuit
Port 8: Detect Open Circuit
ethernet0/0 PSE+
History:
Release
Modification
11.00.06
11.01.01
The
default
option was introduced.
2.3.6 REGISTERS
Displays the internal registers of the device.
Syntax:
2 Monitoring
Teldat SA
12
PoE Power over Ethernet