![Teldat Dm709-I Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/teldat/dm709-i/dm709-i_user-manual_1079560046.webp)
6.3.4.6 SET TI-INACTIVITY-TIMER
Expires when LLC does not receive a frame for a specified time period. When it times out, LLC transmits an RR until
the other LLC station responds or the N2 timer expires. Default is 30 seconds, but options range from 1 to 256. The
disable option deactivates the timer.
Syntax:
<interface name> LLC+set ti-inactivity-timer <session ID> {<value>|default|disable}
Example:
ethernet0/0 LLC+set ti-inactivity-timer 07-04-000c default
Inactivity Timer(Ti) in sec.[30]?
ethernet0/0 LLC+
6.3.4.7 SET TW-TRANSMIT-WINDOW
Sets the maximum number of I-frames that can be sent before receiving an RR. Assuming that the other end of the
LLC session can actually receive this many consecutive I-frames, and the router has enough memory to keep copies
of these frames until an acknowledgment is received, increasing this value may increase the throughput. Values
range from 1 to 127. Default is 2. The disable option deactivates the timer.
Syntax:
<interface name> LLC+set tw-transmit-window <session ID> {<value>|default|disable}
Example:
ethernet0/0 LLC+set tw-transmit-window 07-04-000c 10
ethernet0/0 LLC+
6.3.5 EXIT
Returns to the LAN monitoring menu (Ethernet or Token Ring
)
.
Syntax:
<interface name> LLC+exit
Example:
ethernet0/0 LLC+exit
ethernet0/0 ETH+
6 LLC Monitoring
Teldat SA
40
LAN Interfaces