First steps
Installing base stations and DECT Manager – procedure
¤
When installing the base stations, please take into account the technical conditions for
positioning and the installation guidelines, which are described in the "Gigaset N720 DECT
IP Multicell System -Site Planning and Measurement Guide".
¤
Install the base stations at the positions you determined when planning or measuring your
DECT wireless network.
¤
The elmeg DECT200M (DECT Manager) can be installed anywhere within the range of the
local network. It does not need to be installed in the coverage area of the DECT wireless
network.
¤
The elmeg DECT200 base stations and the elmeg DECT200M DECT Manager are intended for
wall mounting (
Connecting base stations and DECT Manager
To be able to make calls with your elmeg DECT200 Multicell System via VoIP, the following
conditions must be fulfilled:
u
The DECT Manager is installed
u
Your DECT Manager and base station are connected to the local network (
u
At least one base station is registered (
u
At least one handset is registered to the telephone system (
Perform the following steps in the specified sequence, first for the DECT Manager and then for
all the base stations to be installed:
§§1§§
Connect the power cable to the device and connect to the mains power supply, if necessary.
§§2§§
Connect the base to the router/switch to access the local network and configure via the Web
configurator.
§§3§§
Fix the device to the planned position on the wall.
Caution
Read the "Gigaset N720 DECT IP Multicell System - Site Planning and Measurement Guide"
before you start installing the devices.
Caution
u
The devices are designed for use in dry rooms with a temperature range of +5°C to +45°C.
u
Never expose the devices to heat sources, direct sunlight or other electrical appliances.
u
Protect your telephone from moisture, dust, corrosive liquids and fumes.
Please note
Your elmeg DECT200 Multicell System is supplied with sufficient power via PoE (Power over
Ethernet) if the device is connected to an Ethernet switch with PoE functionality (PoE class
IEEE802.3af ). In this case, you do
not
need to connect the device to the mains power supply
and step
§§1§§