Note

Please verify device power input is valid for your power feeding.

There is no on/off switch or fuse. A label on the rear of the equipment contains the power supply information.
Connect the device to a mains socket.
Use a power cord that matches the type of connector on your device and insert it in the appropriate socket.
Now plug the power cord into a power socket. The power LED signals that your device is correctly connected
to the power supply.

Warning

This equipment requires an external overcurrent protection device. To comply with safety regula-
tions, either a 5.0 A time-lag fuse or a previously approved 1-amp thermo-magnetic circuit breaker
(ABB-S281-UC-K-1 or equivalent) must be installed in the power line.

Observe the correct polarity of the DC connection, wrong polarity may destroy the external line fuse.

The device is now ready for configuration.

2.2 Anticorrosion measures to protect the metal parts of the device
during transportation, storing or at its final location

As far as the metal housing is concerned, the APR222ac was designed to be placed in an enclosed location, protec-
ted from bad weather; never to be exposed or subject to these or any other extreme environmental conditions.

The housing is made out of electrogalvanized iron and has an external powder paint coating based on epoxy and
polyester resins, added for aesthetic and anti-corrosion purposes. These characteristics give the housing the ability
to withstand the effects of external corrosive agents (oxidation) to which the device might be exposed during trans-
portation, storage or at its final location. As previously mentioned, these locations must always be indoors, sheltered,
and not exposed to extreme environmental or meteorological conditions.

External paint's resistance to corrosion.

Humidity cabinet

DIN 50017

No change after 500 hours

Salt fog chamber

ASTM B117-97

500 hours

However, there are various considerations and measures that need to be taken into account during the transporta-
tion, storage and final deployment of devices to prevent the metal parts from rusting.

• Devices should be stored indoors or in places that are dry, clean and away

from chemicals.

• Do not subject the devices to sudden rapid changes in temperature that could

lead to condensation (which, in turn, will cause the metal parts in the devices
to rust). Try to maintain the devices at a temperature as constant as possible.

• During transportation and storage, place the device on a wooden or plastic

pallet in order to avoid direct contact with the ground.

Never store the device outdoors. If this is unavoidable, take the following steps and make sure the situation lasts as
little as possible.

• Protect the devices with a waterproof cover (made out of plastic, canvas or a

similar material).

• Try to leave some space between the devices and the waterproof cover to al-

low some air circulation.

• Keep the devices on wooden or plastic pallets and never in direct contact with

the ground. Try to set the pallet at a slight angle to allow any water that might
occasionally collect on the waterproof cover to drain off.

2 Installation

Teldat SA

4

APR222ac

Содержание APR222ac

Страница 1: ...APR222ac Installation Manual Copyright Teldat Dm647 I Version 1 3 2 2019 Teldat SA Teldat SA Manual APR222ac 1...

Страница 2: ...ined in this manual Teldat SA is not liable for any dir ect indirect collateral consequential or any other damage connected to the delivery supply or use of this manual Copyright Teldat SA All rights...

Страница 3: ...2 Software update 7 3 2 System requirements 7 3 3 Preparation 7 3 3 1 Gathering data 7 3 3 2 Configuring a PC 8 3 4 IP configuration 9 3 5 Modify system password 10 3 6 Setting up a wireless network 1...

Страница 4: ...1 User names and passwords in ex works state 20 6 2 2 Logging in for Configuration 20 6 3 Configuration options 21 6 3 1 GUI for advanced users 21 6 3 2 The Setup Tool for experts 28 6 3 3 SNMP shell...

Страница 5: ...ow to access your device from a Windows PC using a current web browser and how to select basic settings Password If you already know how to configure Teldat devices and you want to get started right a...

Страница 6: ...eps in order 1 Antennas Connect the antenna connectors to the antennas to be used with the device 2 Installation Thanks to the brackets in the housing the access points can be fitted to the wall or ce...

Страница 7: ...or or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electrical inspec tion authority or an electrician if you are uncertain that suitable ground...

Страница 8: ...fects of external corrosive agents oxidation to which the device might be exposed during trans portation storage or at its final location As previously mentioned these locations must always be indoors...

Страница 9: ...ean your device easily Use a damp or anti static cloth Do not use solvents Never use a dry cloth since the electrostatic charge could cause electronic failure Make sure that no moisture can enter the...

Страница 10: ...the dynamically assigned IP address please see your DHCP server documentation b Fallback IP address If you do not run a DHCP server you can connect your device directly to your configuration PC and ac...

Страница 11: ...you need to use for configuration purposes meets the necessary requirements Install the Dime Manager software which gives you more tools to work with your device 3 3 1 Gathering data The main data for...

Страница 12: ...tings Windows 7 2 Click on LAN Connection 3 Click on Properties in the status window 4 Look for the Internet Protocol TCP IP entry in the list of network components Installing the Windows TCP IP proto...

Страница 13: ...s Start menu Start Programs Dime Manager The Dime Manager initial screen appears Fig 3 Dime Manager initial screen The Dime Manager detects the devices installed in the network 2 Double click on the d...

Страница 14: ...for as long as said pass word remains unchanged they are not protected against unauthorized use Make sure you change the password to prevent your device from being unduly accessed Proceed as follows...

Страница 15: ...OK Note Windows XP allows several menus to be modified Depending on the configuration the path to the wireless network connection you want to configure may be different to that described above Configu...

Страница 16: ...o your device will be updated automatically When installation of the new software is com plete you will be invited to restart the device Caution After clicking on Go to confirm the update cannot be ab...

Страница 17: ...EDs While the Status LED is permanently lit the device runs through the reset and boot sequence As soon as the Status LED signals normal operation again blinking the reset is complete Release the Re s...

Страница 18: ...Protection Rating IP 30 Solid particle protection 2 5mm Storage temperature 40 C to 85 C Room temperature EN 50155 Class T3 25 70 C 85 C 10 min Relative atmospheric humidity EN 50155 annual average va...

Страница 19: ...on also Error on static Error on blinking Ready WLAN 1 2 green on blinking slowly Free on static At least one client is registered on flickering At least one client is registered and there is data tr...

Страница 20: ...e M12 socket Fig 8 Ethernet 10 100 1000BaseT X M12 8 pin Port The pin assignment is as follows Pinouts for the M12 8 pin Port Pin Connection 1 TRD 1 2 TRD 1 3 TRD 2 4 TRD 2 5 TRD 4 6 TRD 4 7 TRD 3 8 T...

Страница 21: ...ust ensure that your network complies with these restrictions and requirements The requirements for any country may change Teldat SA recommends that you check with local author ities what the latest s...

Страница 22: ...web browser s address field With a DHCP server The IP address that the DHCP server assigned to your device Without a DHCP server With direct connection to the configuration PC fallback IP address 192...

Страница 23: ...0 0 1011 2004 09 07 10 44 12 sshd_host_rsa_key Vrw pl f 0 0 01 730 2004 09 07 10 42 17 sshd_host_dsa_key pub Vrw pl f 0 0 01 796 2004 09 07 10 42 16 sshd_host_dsa_key Flash Sh Note The device generate...

Страница 24: ...ord Authorizations admin admin Read and change system variables save configurations use GUI write public Read and write system variables except passwords changes are lost when you switch off your devi...

Страница 25: ...of connections and configurations Type of connection Possible types of configuration LAN Assistant GUI shell command Note To change the device configuration you must log in with the admin user name I...

Страница 26: ...Enter http 192 168 0 252 or the IP address dynamically assigned by your DHCP server or the address statically assigned by you using Dime Manager in the web browser s address field 5 Enter admin in th...

Страница 27: ...f you need help with the current menu A descrip tion of the sub menu you are currently at will be displayed Logout If you want to end the configuration click on this button to log out of your device A...

Страница 28: ...to the Maintenance Software Con figuration menu select Action Import configuration and click on Go The backup filed is used as the ccurrent boot configuration If you want to load the previously filed...

Страница 29: ...the Sys tem Management Certificates CRLs menu this button activates the sub menus for certificate configuration or CRL imports In the System Management Certificates Certificate List menu this button...

Страница 30: ...n elements Some lists contain configuration elements This means you can change the configuration of the corresponding list entry dir ectly in the list Fig 16 Configuration of the update interval Fig 1...

Страница 31: ...ng on the icon Display of options that are not available Options that are not available because they depend on the selection of other options are generally hidden If dis playing these options proved h...

Страница 32: ...prompt and press Return The main menu of the ASCII Setup Tool opens Setup Tool menu The main menu layout may vary depending on the configuration level of your device Every Setup Tool menu con tains t...

Страница 33: ...cannot be displayed in full A sign at the top right corner indicates the start of the list and a symbol indicates there is more to come Ctrl c Exits the Setup Tool 6 3 2 2 Menu Commands Browsing throu...

Страница 34: ...edit the search string The cursor automatically jumps to the first match it finds with the corresponding initial letters The characters entered for the search are displayed in the help line at the bo...

Страница 35: ...If both entries do not match the field is reset to the old password and the help line shows the following message Password doesn t match Try again 6 3 3 SNMP shell SNMP Simple Network Management Prot...

Страница 36: ...BOOTmonitor prompt is displayed press the space bar in less than four seconds to use the BOOTmonitor functions If you do not make said entry within four seconds the device returns to normal operating...

Отзывы: