8.1 First starting
If the fuel line is empty, the first start-
up may be difficult as the LPG must first take
the place of the air inside it. You may want to
perform a number of attempts.
Before the first starting check the oil level in the
engine (see the chapter concerning mainte-
nance).
Turn the safety switch (fig.16 ref. 1) on the gen-
erator to I.
Set to ON the switch (fig.30 ref. 1) on the control
panel. The ON LED lights up (fig.30 ref. 11); for
one second, the display shows the Telair logo
and the resident software version, then it starts
repeating a sequence of 3 icons:
generator in standby mode
(OFF)
battery voltage
total hours of operation
The generator is on stand-by.
8.2 Information menu
Pressing the MENU key (fig.30 ref. 3) gives ac-
cess to the list of searchable information items;
then, the START/STOP keys (fig.30 ref. 5) and
AUTO key (fig.30 ref. 4) can be used to scroll
forward or backward in the menus:
indicates the number of hours
to the next oil change
indicates the total running
hours
by pressing boost and then
START/STOP or AUTO the last 10 recorded
alarm events can be viewed
indicates the generator model
and hardware and software versions
indicates the language setting;
by pressing BOOST followed by START/STOP or
AUTO it is possible to scroll through the available
languages
end of the available list, by
pressing BOOST the panel is returned to its
standard display mode.
8.3 Language Setting
To select the language in which the display will
show the main messages, press the BOOST but-
ton, then with the START/STOP and AUTO but-
tons scroll through the menus to reach the de-
sired option
Press BOOST to display the message
With the buttons START/STOP and AUTO, scroll
through the available language options, then
press BOOST once again. This will display the
message
then the display will revert to showing again the
generator stand-by state icons sequence.
8.4 Starting the generator in manual mode
Press the START / STOP button: the corre-
sponding LED lights up (fig.30 ref. 9) and the
generator controls the starting procedure; the
display shows the icon
Once the equipment has started, the display re-
peatedly shows the sequence of icons related to
the generator state of operation:
Содержание TIG 3000G
Страница 6: ...TIG 3000 G Vers 001 6 GB THIS PAGE HAS BEEN LEFT BLANK INTENTIONALLY ...
Страница 28: ...TIG 3000 G Vers 001 28 GB 12 TIG 3000 G WIRING DIAGRAM ...
Страница 29: ...Vers 001 TIG 3000 G 29 GB ...
Страница 31: ...Vers 001 TIG 3000 G 31 GB 13 TIG 3000 G SPARE PARTS LIST ...
Страница 32: ...TIG 3000 G Vers 001 32 GB ...
Страница 33: ...Vers 001 TIG 3000 G 33 GB ...
Страница 34: ...TIG 3000 G Vers 001 34 GB ...
Страница 42: ...TIG 3000 G Vers 001 42 GB Notes ...
Страница 43: ...Vers 001 TIG 3000 G 43 GB ...
Страница 44: ......