- 14 -
GB
SPLIT
SPLIT
SPLIT
SPLIT
SPLIT
7000
10
5
INSTALLING THE EVAPORATING
(AERATOR) UNIT
The evaporator unit may be installed in either of two
ways:
using the ventilation holes (rooflight apertures)
already present on the vehicle;
cutting a new hole.
The minimum installation
distance between the evaporating unit, which
contains heating resistors, and any combustible
surface is 500 mm.
5.1 Using the rooflight aperture. and delivered
to Collection and Disposal Centres.
5.2 Opening a new hole
On the roof, chose an central area between two
stanchions and use a felt pen to mark off a square
measuring 400 mm on each side
Fig. 11 Ref. (1)
.
Use a small saw to carefully cut the opening on the
roof. Be careful not to cut any electric wires
Fig. 11
Ref. (2)
.
Wear goggles and safety
gloves before using any electrical/manual tools
or saws.
Place a reinforcing frame (
Fig. 12
) along the profile
of the opening; if necessary, drill a hole on the side
to let through the power cables and refrigerating gas
pipes.
5.3 Positioning the evaporating unit
Before positioning the evaporating unit on the roof
of the vehicle, you must spread a proper amount of
slow-drying sealant around the edges of the opening.
Put the evaporating unit onto the roof of the vehicle
and place it over the opening, previously treated with
the sealant. Make sure that the side holes (which
are on the bottom) Fig. 13 Ref. (1) face the driving
11
1
2
1
2
Содержание ICEBERG SPLIT 7000
Страница 1: ...AIR CONDITIONER V005 February 2005 Split 7000 ENGLISH MANUAL FOR INSTALLATION AND USER MANUAL GB...
Страница 21: ......
Страница 22: ......
Страница 23: ......
Страница 29: ...Split 7000 kit tubes cables Tav 3 Vers 1 del 26 06 2003...
Страница 33: ...33 GB SPLIT SPLIT SPLIT SPLIT SPLIT 7000 NOTES...
Страница 34: ...34 GB SPLIT SPLIT SPLIT SPLIT SPLIT 7000 NOTES...
Страница 35: ...35 GB SPLIT SPLIT SPLIT SPLIT SPLIT 7000 NOTES...