9
Fix a reinforcement frame around the
opening (fig. 5).
4.2.3 Power lead
A 3-core cable with a
2.5 mm²
cross-section
(live-neutral-earth) must be routed for the
power supply of the air conditioner. The wires
at one end must be connected to the thermal
magnetic circuit breaker (recommended load
10 A
) previously installed in the vehicle’s
electrical distribution panel exclusively for the
air conditioner. The other end should reach
the opening made in the roof of the vehicle
and protrude from the hole in the reinforcing
frame by approximately 50 cm in order to
facilitate connection to the air conditioner
(Fig. 6).
The electrical cable must be suitably
protected in order to ensure its integrity and
insulation in all conditions of use of the
vehicle.
4.3 Positioning the air conditioner
Before installation, check that the
cylindrical section seal on the air
conditioner
base
is
still
correctly
positioned inside its special frame seat
(Fig. 7 ref. 1).
Before positioning the air conditioner on the
vehicle roof it is necessary to lay a sufficient
amount of slow-drying sealant around the rim
of the aperture.
Bring the air conditioner onto the roof (fig. 7
ref. 2) and,
without scraping it
, position it
over the 395 x 395 mm opening previously
lined with sealant. Correct alignment of the
air conditioner on the roof will provide a view
- from inside the camper - of the 4 threaded
fixing seats.
The arrow in fig. 7 indicates direction of
forward drive.