![Tektronix WFM4000 Series Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/tektronix/wfm4000-series/wfm4000-series_user-manual_1078259029.webp)
Getting Acquainted With Your Instrument
Ground Closure Interface Connector Pin Assignment
The ground closure interface (GCI) connector uses ground closures for remote control and indicating to external equipment
when alarms have occurred. The input of LTC is through the GCI connector. The GCI connector is a 15-pin D-type connector
with socket contacts.
Table 1: Remote Port
Characteristic
Performance requirement
Reference information
Connector Pin Assignments
Hex
Binary
Pins 15,
14, 13,
12, 11,
10
Direct
mode
selection
Encoded
mode
selection
F
111111
none
No action
E
XX1110
Preset 1
No action
D
XX1101
Preset 2
No action
C
XX1100
SDI B
B
XX1011
Preset 3
SDI A
A
XX1010
No action
9
XX1001
No action
8
XX1000
Preset 8
7
XX0111
Preset 4
Preset 7
6
XX0110
Preset 6
5
XX0101
Preset 5
4
XX0100
Preset 4
3
XX0011
Preset 3
2
XX0010
Preset 2
1
XX0001
Preset 1
0
XX0000
Unused
N/A
101111
Preset 5
N/A
1 GND (In)
2 Reserved (I/O)
3 Reserved (I/O)
4 Reserved (In)
5 Reserved (In)
6 GND (In)
7 Time Code Positive (LTC In)
8 Time Code Negative (LTC In)
9 Ground Closure (Alarm Out)
10 Preset 1 (In)
11 Preset 2 (In)
12 Preset 3 (In)
13 Preset 4 (In)
14 Preset 5 (In)
15 Preset 6 (In)
N/A
011111
Preset 6
N/A
Ethernet Connector
The instrument provides a 10/100
BaseT Ethernet interface. The
Ethernet connector is a standard
RJ-45 connector.
WFM4000 and WFM5000 Waveform Monitors User Manual
13
Содержание WFM4000 Series
Страница 1: ...x WFM4000 and WFM5000 Waveform Monitors ZZZ User Manual P077243802 077 2438 02 ...
Страница 2: ......
Страница 3: ...WFM4000 and WFM5000 Waveform Monitors ZZZ User Manual xx Revision A www tektronix com 077 2438 02 ...
Страница 6: ......
Страница 16: ...Preface x WFM4000 and WFM5000 Waveform Monitors User Manual ...
Страница 76: ...Upgrading Instrument Software 60 WFM4000 and WFM5000 Waveform Monitors User Manual ...