Circuit Description— Type 109
CHARGE LINE
WAVEFORM AT
CH G. LINE 1
AND 2 CONNECTORS
WAVEFORM AT
SO
Q
OUTPUT
CONNECTOR
Dip due to capacitive
Dip due to capacitive
coupling of backwave
coupling of backwave
Reed closes
Contact Reed closes Contact Reed closes Contact
with left
opens
with right
opens
with left
opens
contact
contact
contact
F ig . 4 - 4 .
C h a rg e a n d d isc h a rg e seq u e n ce usin g the sam e ch a rg e lin e . T y p e 1 0 9 output am p litu d e
is + 5 0 vo lts a n d the n o m in a l re p e titio n ra te is 6 4 0 cps.