Command Descriptions
2–54
TDS Family Oscilloscope Programmer Manual
ALLOcate:WAVEform:REF<x>
Sets or queries the number of waveform data points for the specified reference
location. If an attempt is made to allocate memory when it is not available, an
execution error is generated and the memory is not allocated.
Save and Recall
= 0 is returned when the reference location is empty.
0 specifies the number of data points. Table 2–23 shows the number of
data points supported for reference locations by TDS model. In the TDS 5XXA
and 6XXA, all invalid values less than the maximum will be forced to the next
highest valid value, and those higher than the maximum will be forced to the
maximum. For example, 15002 points on a TDS 544A with option 1M will
allocate 50000 points of data for the reference. No complete references are stored
for 500000 data points in the TDS 7XXA.
Table 2–23: Waveform Data Points Supported for Reference Locations
Configuration
TDS 410A,
TDS 420A,
TDS 460A
TDS 520A,
TDS 524A,
TDS 540A,
TDS 544A
TDS 620A,
TDS 640A,
TDS 644A
TDS 684A
TDS 744A,
TDS 784A
Standard
500,
1000,
2500,
5000,
15000,
30000 (4 refs)
500,
1000,
2500,
5000,
15000
500,
1000,
2000
500,
1000,
2500,
5000,
15000
500,
1000,
2500,
5000,
15000,
50000 (4 refs)
Option 1M
60000 (2 refs),
120000 (1 ref)
50000
75000 (3 refs),
100000 (2 refs),
130000 (2 refs),
250000 (1 ref)
500000 (no
complete refs)
Group
Syntax
Arguments
Содержание TDS 410A
Страница 4: ......
Страница 10: ...Table of Contents vi TDS Family Oscilloscope Programmer Manual ...
Страница 56: ...Command Groups 2 38 TDS Family Oscilloscope Programmer Manual ...
Страница 346: ...Status and Events 3 20 TDS Family Oscilloscope Programmer Manual ...
Страница 352: ...Program Examples 4 6 TDS Family Oscilloscope Programmer Manual ...
Страница 358: ...Appendix B Reserved Words B 4 TDS Family Oscilloscope Programmer Manual ...