Remote Commands
7–72
ST112 SONET Transmission Test Set
Loss Of Signal
los_enab
Loss Of Signal Enable Command
Enables the LOS event for the amount of time specified by los_time.
Example:
los_enab
Response:
NONE
los_time [ n ]
Loss Of Signal Time Command
Set Loss of Signal event to a specific amount of time from 1 to 127 microseconds
Example:
los_time
50
Response:
NONE
Note:
In the example the LOS will last for 50 microseconds
los_time?
Loss Of Signal Time Query Command
Returns the LOS time duration in microseconds
Example:
los_time?
Response:
LOS_TIME n (n = a decimal quantity from 1 to 127 microseconds)
los_secs n.m
Sets the timed LOS event to a duration from 1.0 to 9.9 seconds
Example:
los_secs n.m (n.m = a decimal number from 1.0 to 9.9)
Response:
NONE
los_tm_enab
Enables the LOS event for the amount of time specified by los_secs command.
Example:
los_tm_enab
Response:
NONE
los_off
Disables the LOS event currently being generated.
Example:
los_off
Response:
NONE
los_cont
Generates a continuous LOS event.
Example:
los_cont
Response:
NONE