Remote Commands
7–28
ST112 SONET Transmission Test Set
test_report [ log | eot | both | off ]
Test Report Set Command
Enable or disable Test Report Type.
Arguments
log: enable event log reports
eot: enable end-of-test reports.
both: enable both log and eot reports.
off: disables reports.
Example: test_report
both
Response:
NONE
test_report?
Test Report Query Command
Returns a character string indicating the report status.
Example: test_report?
Response:
TEST_REPORT
BOTH
Note:
See the Test Report Set Command
test_squelch [ on | off ]
Test Squelch Set Command
Enables or disables the Squelch.
Arguments
on: (1) logs 10 consecutive events (2) waits for 10 event free seconds.
off: logs every event.
Example: test_squelch
on
Response:
NONE
Note:
When the Squelch is enabled error logging is limited to ten consecutive
reports. Then Error logging is resumed after 10 event free seconds.
test_squelch?
Test Squelch Query Command
Returns the current status of the Squelch
Example: test_squelch?
Response:
TEST_SQUELCH
ON
Note:
See the Test Squelch Set Command.
test_state [ run | stop ]
Test State Set Command
Sets the test state to either run or stop.
Arguments
run: clears all counters, clears the history, and starts the test cycle.
stop: suspends the test cycle.
Example: test_state
run
Response:
NONE
Note:
See pause_state command.
The Trouble Scan Mode must be OFF before the Test State can be enabled.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com