Remote Commands
7–64
ST112 SONET Transmission Test Set
tx_vt_v5 [n] Transmit V5 Byte Set Command
Sets the (VT1.5) V5 overhead byte to a decimal value from 0 to 63.
Example:
tx_vt_v5 [n] (n = a number from 0 to 63 decimal.)
Response:
NONE
Notes:
The V5 byte bit positions are numbered from 1 (msb) to 8 (lsb).
bits 1 and 2 are inaccessible
bit 3 = VT Path FEBE (20 hex = 32 decimal)
bit 4 is Unassigned (10 hex = 16 decimal)
bits 5, 6, 7 = VT Path Signal Label (listed below, in binary)
0 0 0 VT SPE Unequipped (00 hex = 0 decimal)
0 0 1 VT SPE Equipped—Payload Not Specified (02 hex = 2 decimal)
0 1 0 VT SPE Equipped—Unassigned (04 hex = 4 decimal)
0 1 1 VT SPE Equipped—Unassigned (06 hex = 6 decimal)
1 0 0 VT SPE Equipped—Unassigned (08 hex = 8 decimal)
1 0 1 VT SPE Equipped—Unassigned (0A hex = 10 decimal)
1 1 0 VT SPE Equipped—Unassigned (0C hex = 12 decimal)
1 1 1 Alarm Indication Signal (0E hex = 14 decimal)
bit 8 = Yellow Signal (01 hex = 1 decimal)
tx_vt_v5?
Transmit V5 Byte Query Command
Returns the decimal value of the (VT1.5) V-5 overhead byte.
Example:
tx_vt_v5?
Response:
TX_VT_V5
14
Note:
See the Transmit V5 Byte Set Command (tx_vt_v5 [n])
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com