Operating Information
SDA 601 Serial Digital Analyzer
2- 11
month abbreviations are the first three characters of the English name: JAN;
FEB; MAR; APR; MAY; JUN; JUL; AUG; SEP; OCT; NOV; DEC.
Enter the time in 24 hour format; that is, if the present time is 4:15 pm, enter
16:15.
4.
When the correct date and time is shown on the display, press
Enter
. If all
values are valid, the instrument will respond with the message “Time
Accepted.” If you have made an error and entered an invalid date or time, the
instrument will respond with an appropriate error message. If that happens,
correct the error and press enter.
5.
Press any rectangular key to exit the Utility menu, or proceed to other
preliminary settings, as appropriate.
Confirm that the Battery Type setting is correct, and change it if necessary.
1.
After setting the clock, press the
B
key once to scroll to the Diagnostics
submenu item, and press
Enter
.
2.
In the Diagnostics submenu, scroll down to the Power Manage item with the
B
key. Again, press
Enter
.
3.
The top item in the Power Manage submenu is Battery Type. Toggle to the
selection that matches the type of battery you have installed in your
SDA601 by pressing either
A
or
"
. The choices are “rechargeable” and
“disposable.” Select rechargeable when using NiCad AA cells or the optional
battery pack; choose disposable when you are using common Alkaline AA
batteries, which cannot be recharged. Press
Enter
to confirm the choice.
4.
When the correct battery type is indicated by an asterisk (*) on the lower
right of the LCD, continue to Auto Power Off, or press any rectangular key
to exit the Utility/Diagnostics/Power Manage submenu and return to normal
operation.
“Auto Power Off” will switch the instrument off when ten minutes have passed
without a key press. Enable this feature when you are using battery power and
operating in an environment in which unplanned shutdown of the SDA601 is
permissible.
1.
While still in the Utility/Diagnostics/Power Manage submenu, press the
B
key twice to scroll to the Auto Power Off item.
2.
Disable/enable Auto Power Off by pressing either
A
or
"
. Press
Enter
to
confirm the choice. Enabled Auto Power Down is indicated by a “rotating
line” symbol on the second line of the instrument display, and in the
lower-left corner of the OSD.
Set the Battery Type
Enable (Disable) Auto
Power Off
Содержание SDA601
Страница 4: ......
Страница 10: ......
Страница 15: ...Specifications...
Страница 16: ......
Страница 21: ...Operating Information...
Страница 22: ......
Страница 29: ...Operating Information SDA 601 Serial Digital Analyzer 2 7 Figure 2 5 A Printed Analysis Report...
Страница 49: ...Performance Verification...
Страница 50: ......
Страница 69: ...Adjustment Procedures...
Страница 70: ......
Страница 78: ...Adjustment Procedures 4 8 SDA 601 Serial Digital Analyzer...
Страница 79: ...Maintenance...
Страница 80: ......
Страница 93: ...Replaceable Electrical Parts...
Страница 94: ......
Страница 104: ......
Страница 105: ...Diagrams...
Страница 106: ......
Страница 108: ...Diagrams and Circuit Board Illustrations 7 2 SDA 601 Serial Digital Analyzer Data Path Diagram...
Страница 111: ......
Страница 122: ......
Страница 123: ...Replaceable Mechanical Parts...
Страница 124: ......
Страница 129: ...Index...
Страница 130: ......