background image

Service Manual

RTX100A
ISDB-T RF Signal Generator

071-1757-00

Warning

The servicing instructions are for use by qualified

personnel only. To avoid personal injury, do not

perform any servicing unless you are qualified to

do so. Refer to all safety summaries prior to

performing service.

www.tektronix.com

Содержание RTX100A

Страница 1: ...071 1757 00 Warning The servicing instructions are for use by qualified personnel only To avoid personal injury do not perform any servicing unless you are qualified to do so Refer to all safety summa...

Страница 2: ...and pending Information in this publication supercedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tek...

Страница 3: ...ponsible for paying all shipping charges duties taxes and any other charges for products returned to any other locations This warranty shall not apply to any defect failure or damage caused by imprope...

Страница 4: ......

Страница 5: ...ifications 1 3 Performance Conditions 1 3 Functional Specifications 1 3 Electrical Specifications 1 4 Mechanical Physical Characteristics 1 11 Environmental Characteristics 1 11 Certifications and Com...

Страница 6: ...Modules 5 15 Procedure for Board Modules 5 21 Procedure for Internal Modules 5 26 Setting the BIOS Configuration 5 35 Procedure 5 35 Troubleshooting 5 37 Troubleshooting Trees 5 37 Using the Recovery...

Страница 7: ...14 Figure 3 7 Equipment connection for checking the record operation ASI interface 3 15 Figure 3 8 Equipment connection for checking the recorded file ASI interface 3 17 Figure 3 9 Fifth equipment con...

Страница 8: ...hooting procedure 1 5 38 Figure 5 17 Troubleshooting procedure 2 5 39 Figure 5 18 Troubleshooting procedure 3 5 40 Figure 5 19 Troubleshooting procedure 4 5 41 Figure 5 20 Troubleshooting procedure 5...

Страница 9: ...Table 1 5 Certifications and compliances 1 12 Table 3 1 Equipment required for performance verification 3 1 Table 3 2 Output channel and center frequency settings 3 22 Table 4 1 Equipment required 4...

Страница 10: ...Table of Contents vi RTX100A ISDB T RF Signal Generator Service Manual...

Страница 11: ...All Terminal Ratings To avoid fire or shock hazard observe all ratings and markings on the product Consult the product manual for further ratings information before making connections to the product...

Страница 12: ...r property Terms on the Product These terms may appear on the product DANGER indicates an injury hazard immediately accessible as you read the marking WARNING indicates an injury hazard not immediatel...

Страница 13: ...his product unless another person capable of rendering first aid and resuscitation is present Disconnect Power To avoid electric shock disconnect the mains power by means of the power cord or if provi...

Страница 14: ...Service Safety Summary x RTX100A ISDB T RF Signal Generator Service Manual...

Страница 15: ...eused or recycled appropriately The symbol shown to the left indicates that this product complies with the European Union s requirements according to Directive 2002 96 EC on waste electrical and elect...

Страница 16: ...Environmental Considerations xii RTX100A ISDB T RF Signal Generator Service Manual...

Страница 17: ...ns contains a description of the RTX100A and the characteristics that apply to it H Theory of Operation contains circuit descriptions that support service to the module level H Performance Verificatio...

Страница 18: ...ections Italics are also used in NOTES CAUTIONS and WARNINGS Example The Diagrams section beginning on page 7 1 includes a block diagram and an interconnect diagram Throughout this manual any replacea...

Страница 19: ...in Section 3 Performance Verifica tion should be done every 12 months In addition a performance check is recommended after module replacement If the RTX100A does not meet performance criteria repair i...

Страница 20: ...e year from date of purchase The warranty appears after the title page in this manual Tektronix technicians provide warranty service at most Tektronix service locations The Tektronix product catalog l...

Страница 21: ...Specifications...

Страница 22: ......

Страница 23: ...RAM mode 256 Kbps minimum H Hierarchy display of stored or captured transport streams H 188 204 208 bytes packet size S TMCC M TMCC non transport stream and partial transport stream output formats H...

Страница 24: ...Product Overview 1 2 RTX100A ISDB T RF Signal Generator Service Manual...

Страница 25: ...itions H The RTX100A must be in an environment where the temperature altitude humidity and vibration conditions are within the operating limits described in Table 1 4 on page 1 11 H The RTX100A must h...

Страница 26: ...clock 27 MHz 1 ppm External reference clock input Connector type BNC Input impedance typical 50 Reference input Frequency 8 129698 MHz 10 MHz and 27 MHz Input level typical Sine wave 0 6 dBm Vp p Squ...

Страница 27: ...arallel clock 214 MHz maximum 15632 X 31248 1 Y 16383 2 Z 65536 External serial clock TS clock X 2 Y Z external serial clock 8 32 MHz maximum 15632 X 31248 1 Y 16383 2 Z 65536 P N and Jitter serial cl...

Страница 28: ...output connectors as the SMPTE310M interface Standard conformance EN 50083 9 Annex B Connector type BNC Impedance 75 Data rate 256 Kbps to 214 Mbps Output Number of outputs 1 Output voltage 800 mV 10...

Страница 29: ...Frequency 470 to 770 MHz channel plan steps Channel Frequency Channel Frequency Channel Frequency 13 473 143 30 575 143 47 677 143 14 479 143 31 581 143 48 683 143 15 485 143 32 587 143 49 689 143 16...

Страница 30: ...PP Enhanced Parallel Port and ECP Extended Capabilities Port modes Connector type D sub 25 pin Pin assignments 1 STROBE 14 AUTOLF 2 D0 15 ERR 3 D1 16 INIT 4 D2 17 SELECT 5 D3 18 GND 6 D4 19 GND 7 D5 2...

Страница 31: ...3 TX 8 CTS 4 DTR 9 RI 5 GND IEEE1394B interface Compliant IEEE1394B 2002 Pin assignments 1 TPB 6 VG 2 TPB 7 NC 3 TPA 8 VP 4 TPA 9 TPB R 5 TPA R AC line power Rating Voltage 100 VAC to 240 VAC CAT II...

Страница 32: ...a delay Input clock pulse width Input data hold time Th T 2 T 10 T f 1 5 ns 5 ns In the universal parallel serial interface the polarity of DCLK can be inverted Th T 2 T 10 SPI and universal parallel...

Страница 33: ...0 _C Relative humidity Operating 20 to 80 No condensation Maximum wet bulb temperature 29 _C Non operating 5 to 90 No condensation Maximum wet bulb temperature 29 _C Altitude Operating Up to 4 5 km 15...

Страница 34: ...ent for Class A electrical equipment for measurement control and laboratory use EN 61000 3 2 AC Power Line Harmonic Emissions IEC 61000 4 2 Electrostatic Discharge Immunity Performance Criterion B IEC...

Страница 35: ...C 61010 1 Pollution Degree A measure of the contaminates that could occur in the environment around and within a product Typically the internal environment inside a product is considered to be the sam...

Страница 36: ...Specifications 1 14 RTX100A ISDB T RF Signal Generator Service Manual...

Страница 37: ...Theory of Operation...

Страница 38: ......

Страница 39: ...ket Type Controller This controller sets a packet size of 188 204 208 and Non TS free length as a TS packet type For a Non TS format the controller also sets a packet length 16 255 and data length 16...

Страница 40: ...This counter can be read by the control software Receive Rate Counter This circuit detects receive rate Its status is updated every 50 ms The interrupt controller sends the following interruption sign...

Страница 41: ...is sent to BIOS and the PSON signal turns high This circuit includes a 12 V to 5 V DC DC converter a 12 V to 3 3 V converter and a 12 V to 12 V converter There are four connectors in the interconnect...

Страница 42: ...also generates an interrupt signal when an IIP of a transport stream is decoded and Mode is changed This block performs coding of ISDB T It has four synchronous SRAMs as buffers for interleaving This...

Страница 43: ...and 4 bits of Hsync Vsync DE and CNTL The video inverter circuit consists of an FPGA and SRAM The circuit converts the display data upside down because the LCD display is attached to the chassis upsi...

Страница 44: ...Theory of Operation 2 6 RTX100A ISDB T RF Signal Generator Service Manual...

Страница 45: ...Performance Verification...

Страница 46: ......

Страница 47: ...TS400 Function generator 1 Frequency 40 M clock pattern Amplitude 3 V Outputs 2 channel Tektronix AFG3102 Oscilloscope 1 Bandwidth 1 GHz or higher Tektronix TDS5104B ISDB T analyzer 1 Panasonic VP8480...

Страница 48: ...he equipment required to perform the test H Each test contains complete setup instructions which allows you to perform each test individually or in order H The equipment connection illustrations are s...

Страница 49: ...tor on the RTX100A to the oscilloscope CH1 input See Figure 3 1 Oscilloscope TDS5104B 50 BNC cable RTX100A rear panel Figure 3 1 Equipment connection for checking the internal clock output level 2 Sel...

Страница 50: ...alues are as follows High Level 2 2 V Low Level 0 8 V 7 Disconnect the 50 BNC cable from the oscilloscope CH1 input and then connect the BNC cable to the CH1 connector on the frequency counter See Fig...

Страница 51: ...RTX100A Equipment i d MPEG analyzer q p required Parallel interface cable test40 TRP file Checking the Play Operation 1 Use the parallel interface cable to connect the SPI In Out connector on the RTX1...

Страница 52: ...n on the RTX100A to start playing the test40 TRP file 8 Verify that the hierarchic view is displayed on the MPEG analyzer screen In addition verify that the bit rate is 214 Mbps and the packet size is...

Страница 53: ...y is 188 bytes 20 Press the REC button on the RTX100A to record the file 21 After recording is completed click the Stop button on the MPEG analyzer 22 Exit the MPEG Player application on the MPEG anal...

Страница 54: ...yzer window This test confirms that the external clock reference input Clock Ref In and external trigger input Trig In Out on the RTX100A are functioning correctly Equipment i d MPEG analyzer q p requ...

Страница 55: ...ettings as indicated below Ch 1 output Function Square Run Mode Continuous Frequency 10 MHz Output Amplitude 0 5 V Output Offset 2 0 V Ch 2 output Function Arb Edit Point Number 100 All Data 16382 Run...

Страница 56: ...In addition verify that the bit rate is 64 Mbps and the packet size is 188 bytes NOTE Ignore Program 3 and PID 120 0x78 errors in the hierarchical view because these are caused by the original test40...

Страница 57: ...ator to start the signal output 26 Select Play Others on the RTX100A to open the Others dialog box 27 In the dialog box set Ext Play Start to Rise 28 Verify that the RTX100A starts playing when the Ou...

Страница 58: ...uired Oscilloscope MPEG 2 measurement decoder Video monitor Two 75 BNC cables 75 signal adapter test40 TRP file Checking the Output Signal 1 Use the 75 BNC cable and the 75 signal adapter to connect t...

Страница 59: ...l 0 V Trigger slope Rising Edge Input coupling DC Measure Amplitude Rise Time Fall Time Gating Cursor Curs1 Pos1 2 5 ns Curs2 2 75 ns 3 Open the test40 TRP file on the RTX100A a Select File Open in th...

Страница 60: ...6 MPEG analyzer rear panel MTS430 75 BNC cable RTX100A rear panel Figure 3 6 Equipment connections for checking the play operation ASI interface 7 Start the MPEG Player application on the MPEG analyze...

Страница 61: ...is 214 Mbps and the packet size is 188 bytes 13 Click the Record button on the MPEG Player application to record the file 14 After recording is completed press the STOP button on the RTX100A 15 Discon...

Страница 62: ...d_Files directory and then select the ASI214Mbps trp file 22 On the MPEG player make the following settings Play Clock Data Rate 214 Mbps Update Off Source RAM SPI ASI 310M BNC Port ASI Through Out Of...

Страница 63: ...ate On 32 Open the ASI214Mbps file on the RTX100A a Select File Open to open the Select File dialog box b In the dialog box navigate to the D Record_Files directory and then select the ASI214Mbps trp...

Страница 64: ...re 40 Use a 75 BNC cable to connect the ASI Out connector on the RTX100A to the TS ASI connector on the MPEG 2 measurement decoder See Figure 3 9 41 Use the 75 BNC cable to connect the SER75 connector...

Страница 65: ...he RTX100A MPEG 2 measurement decoder and video monitor This test verifies the carrier frequency carrier leakage and output level error of the RF output The following equipment is required for this te...

Страница 66: ...ISDB T Calibration dialog box appears 4 In the dialog box set Reference Frequency to 13 and then select the Cal Signal check box 5 Set the frequency counter settings as indicated below MEASURE Frequen...

Страница 67: ...N Ma adapter 75 BNC Ma to NC Fe adapter 50 N Ma to SMA Fe adapter Figure 3 11 Equipment connection for checking the carrier leakage 14 Set the spectrum analyzer settings as indicated below CENTER FREQ...

Страница 68: ...05 143 52 707 143 19 509 143 36 611 143 53 713 143 20 515 143 37 617 143 54 719 143 21 521 143 38 623 143 55 725 143 22 527 143 39 629 143 56 731 143 23 533 143 40 635 143 57 737 143 24 539 143 41 641...

Страница 69: ...nt 26 Change frequency offset of each marker and verify that each value meets the condition as follows Delta marker Marker 1 2 86 MHz 20 dB Delta marker Marker 2 3 00 MHz 27 dB Delta marker Marker 3 4...

Страница 70: ...RF Parameter dialog box 36 In the dialog box set Center Frequency to 13 37 Open the ISDB_T_M3 rmx file on the RTX100A a Select File Open to open the Select File dialog box b In the dialog box navigat...

Страница 71: ...5 for Channel 15 to Channel 62 47 Change the demodulation DEMODSET settings to Mode 2 on the ISDB T analyzer 48 Open the ISDB_T_M2 rmx file on the RTX100A a Select File Open to open the Select File di...

Страница 72: ...connection for checking the IEEE1394b interface 2 Select Play Minimize to minimize the RTX100A application 3 Power on the IEEE1394b hard disk drive 4 Double click the My Computer icon on the Windows...

Страница 73: ...Adjustment Procedures...

Страница 74: ......

Страница 75: ...he specification Equipment Required Table 4 1 lists the test equipment required to adjust the carrier leakage The table identifies examples of recommended equipment and lists the required precision wh...

Страница 76: ...Fe adapter 50 N Fe to 75 N Ma adapter 75 BNC Ma to NC Fe adapter 50 N Ma to SMA Fe adapter Figure 4 1 Equipment connection for adjusting the carrier leakage 2 Set the spectrum analyzer settings as ind...

Страница 77: ...cy settings for the spectrum analyzer are indicated by boldface in the Table 4 2 Table 4 2 Output channel and center frequency settings CH Center Frequency MHz CH Center frequency MHz CH Center freque...

Страница 78: ...Adjustment Procedures 4 4 RTX100A ISDB T RF Signal Generator Service Manual...

Страница 79: ...Maintenance...

Страница 80: ......

Страница 81: ...isolating and troubleshooting failed modules Troubleshooting trees are included H Using the Recovery Discs Procedures for reinstalling the Windows XP operating system and the RTX100A application if t...

Страница 82: ...ing of static sensitive modules 2 Transport and store static sensitive modules in their static protected containers or on a metal rail Label any package that contains static sensitive modules 3 Discha...

Страница 83: ...ront panel and display from dust and damage Install the front cover when storing or transporting the RTX100A Inspect and clean the RTX100A as often as operating conditions require The collection of di...

Страница 84: ...or parts of items bent pins broken or frayed cables and damaged connec tors Repair or replace damaged or missing items frayed cables and defective modules Cleaning Procedure Exterior To clean the RTX1...

Страница 85: ...a fresh module Resistors Burned cracked broken blis tered condition Remove failed module and replace with a fresh module Solder connections Cold solder or rosin joints Resolder joint and clean with is...

Страница 86: ...ing steps 3 If steps 1 and 2 do not remove all the dust or dirt the RTX100A may be spray washed using a solution of ethyl alcohol by performing steps 4 through 8 4 Gain access to the parts to be clean...

Страница 87: ...tools required to remove and disassemble all modules H Three module locator diagrams for finding the External modules see Figure 5 2 on page 5 11 Board modules see Figure 5 3 on page 5 12 and Interna...

Страница 88: ...in this section In addition you can look up any procedure for removal and reinstallation of any module in the Table of Contents of this manual H The Access Procedure on page 5 14 first directs you to...

Страница 89: ...move or install a screw unless a different size screwdriver is specified in that step All equipment required to remove and reinstall each module is listed in the first step of its procedure Table 5 4...

Страница 90: ...gnal Generator Service Manual In this manual procedures refer to front back and top of the RTX100A Figure 5 1 shows how the sides are referenced Figures 5 2 through 5 4 show the modules that make up t...

Страница 91: ...X100A ISDB T RF Signal Generator Service Manual 5 11 Left side cover Cabinet Front cover LCD module Bracket A35 Power Switch board A30 Front Panel board Front panel Rubber switch Display filter Right...

Страница 92: ...Installation Procedures 5 12 RTX100A ISDB T RF Signal Generator Service Manual A20 PCI Backplane board A150 ISDB T RF Output board A12 Main board CPU board Printer connector Blank panel Figure 5 3 Bo...

Страница 93: ...ocedures RTX100A ISDB T RF Signal Generator Service Manual 5 13 DVD drive Hard disk drive External fan Internal fan RFI filter 12 V main power supply A40 AC Distributer board Hard disk drive retainer...

Страница 94: ...4 Procedures for External Modules Cabinet p 5 15 Right side cover p 5 16 Left side cover p 5 16 Front panel unit p 5 18 Front panel assembly p 5 19 Do the procedures Cabinet and Right and Left Covers...

Страница 95: ...5 Torx tip b Locate the cabinet in the locator diagram External modules Figure 5 2 on page 5 11 2 Orient the instrument Set the RTX100A so its bottom is down on the work surface and its rear is facing...

Страница 96: ...he instrument Set the RTX100A so its left side is down on the work surface and its front is facing you 3 Use a screwdriver with a T 10 Torx tip to remove the seven screws securing the right side cover...

Страница 97: ...RTX100A so its right side is down on the work surface and its front is facing you 3 Use a screwdriver with a T 10 Torx tip to remove the six screws securing the left side cover to the top and bottom...

Страница 98: ...bottom is down on the work surface and its front is facing you 3 Remove front panel unit See Figure 5 8 a Use a screwdriver with a T 10 Torx tip to remove the four screws securing the front panel unit...

Страница 99: ...a Disconnect the cables from J100 J300 and J320 on the A30 Front Panel board b Use a screwdriver with with a T 10 Torx tip to remove the four screws securing the A30 Front Panel board to the front co...

Страница 100: ...nstallation Procedures 5 20 RTX100A ISDB T RF Signal Generator Service Manual A35 Power Switch board A30 Front Panel board Front cover bracket LCD module Front cover Figure 5 9 Disassembly of front pa...

Страница 101: ...moved H You need a screwdriver with a T 10 Torx tip 2 Orient the instrument Set the RTX100A so its bottom is down on the work surface and its right side is facing you 3 Remove the board retainers See...

Страница 102: ...B T RF Signal Generator Service Manual Top frame A20 PCI Backplane board CPU board A12 Main board A150 ISDB T RF Output board Board retainer Printer connector Figure 5 10 A150 RF Output board A12 Main...

Страница 103: ...removed a You need a screwdriver with a T 10 Torx tip b Locate the A12 Main board in the locator diagram Board modules Figure 5 3 on page 5 12 2 Orient the instrument Set the RTX100A so its bottom is...

Страница 104: ...E After you replace the CPU board you must set the BIOS configuration Refer to Setting BIOS Configuration on page 5 35 1 Assemble equipment and locate module to be removed a You need a screwdriver wit...

Страница 105: ...ed a You need a screwdriver with a 1 4 inch nut driver b Locate the connector in the locator diagram Board modules Figure 5 3 page 5 12 2 Orient the instrument Set the RTX100A so its bottom is down on...

Страница 106: ...gure 5 4 page 5 13 2 Orient the instrument Set the RTX100A so its bottom is down on the work surface and its front is facing you 3 Remove the DVD drive See Figure 5 11 a Remove the front panel unit as...

Страница 107: ...hard disk drive in the locator diagram Internal modules Figure 5 4 page 5 13 2 Orient the instrument Set the RTX100A so its bottom is down on the work surface and its left side is facing you 3 Remove...

Страница 108: ...Generator Service Manual d Grasp the hard disk drive and pull it gently away from the chassis 4 Reinstallation Perform step 3 in reverse order to reinstall the hard disk drive Hard disk drive unit Ha...

Страница 109: ...tor diagram Internal modules Figure 5 4 page 5 13 2 Orient the instrument Set the RTX100A so its bottom is down on the work surface and its front is facing you 3 Remove the internal fan See Figure 5 1...

Страница 110: ...Removal and Installation Procedures 5 30 RTX100A ISDB T RF Signal Generator Service Manual Internal fan External fan Figure 5 13 Internal and external fan removal...

Страница 111: ...er supply away from the chassis 4 Reinstallation Perform step 3 in reverse order to reinstall the 12 V main power supply 1 Assemble equipment and locate modules to be removed a You need a screwdriver...

Страница 112: ...d a You need a screwdriver handle a T 10 Torx tip and a T 15 Torx tip b Locate the RFI filter in the locator diagram Internal modules Figure 5 4 page 5 13 2 Orient the instrument Set the RTX100A so it...

Страница 113: ...screwdriver with a T 10 Torx tip to remove the two screws securing the RFI filter to the chassis d Pull the RFI filter away from the chassis 4 Reinstallation Perform step 3 in reverse order to reinsta...

Страница 114: ...Removal and Installation Procedures 5 34 RTX100A ISDB T RF Signal Generator Service Manual...

Страница 115: ...S Setup Utility screen appears 3 Use the arrow keys to select Load Optimized Defaults and then press the Enter key The Load Optimized Defaults Y N message appears 4 Enter Y and then press the Enter ke...

Страница 116: ...rator Service Manual PC Health Status CPU Warning Temperature 66 _C 151 _F Shutdown Temperature 70 _C 158 _F 6 Use the arrow keys to select Save Exit Setup and then press the Enter key The Save to CMO...

Страница 117: ...r Service Manual 5 37 Troubleshooting This subsection contains troubleshooting trees designed to isolate faulty modules in the RTX100A Troubleshooting Trees Figures 5 16 through 5 22 show the troubles...

Страница 118: ...No Does the RTX100A application start up normally To C page 5 44 H Replace the CPU board H Replace the hard disk drive H Make the BIOS setting again No H Check that the A12 Main board and the interfac...

Страница 119: ...PI In Out connector Can a stream data be output from the ASI Out connector Yes No Can a stream data be acquired from the ASI In connector To E page 5 45 H Check the cable 174 B924 00 H Replace the int...

Страница 120: ...an RF modulated signal be output from the RF Out connector Replace the A150 ISDB T RF Output board Connect an ISDB T receiver to the RF Out connector and play an ISDB T transport stream file Connect a...

Страница 121: ...174 5173 00 cables H Check the ON STBY switch on the A35 Power switch board No H Check the 174 5174 00 cable H Replace the CPU board No Remove the A12 Main board or the optional interface module if in...

Страница 122: ...ule if installed which affects the power supply Yes No 3 Are all the voltages 5 V 3 3 V 12 V and 12 V correct H If the other voltage is faulty replace the A20 PCI Backplane board H If the 12 V line is...

Страница 123: ...002 00 cable H Replace the A30 Front Panel board Replace the CPU board B Does the backlight light Yes No H Check the 174 5184 00 and 174 5220 00 cables H Replace the A35 Power switch board Connect a V...

Страница 124: ...gone off No Yes D Is the SPI Output Enable check box in the Others dialog box selected Replace the A12 Main board Reinstall the Windows XP operating system and the RTX100A application H Replace the A...

Страница 125: ...Yes E Is the Record Source menu set to SPI Replace the A12 Main board Select Record Source SPI Can a stream data be acquired from the SPI In Out connector Yes Done No Figure 5 23 Troubleshooting proce...

Страница 126: ...Troubleshooting 5 46 RTX100A ISDB T RF Signal Generator Service Manual J240 Front J230 Figure 5 25 A20 PCI Backplane board view right side...

Страница 127: ...perating system 1 Insert the Windows XP Professional Operating System Recovery Disc into the DVD drive 2 Turn off then turn on the instrument The RTX100A runs from the disc 3 Follow the installation i...

Страница 128: ...he License Agreement window appears 4 Select I accept the terms in the license agreement and then click Next The Destination Folder window appears 5 Click Next The Setup Type window appears 6 Select C...

Страница 129: ...25 SUBSYS_80251268 REV 5 23d05aab 0 3068F0 Device Parameters 4 In the file list on the right side of the window double click the SidSpeed icon This opens the Edit DWORD Value dialog box 5 In the Edit...

Страница 130: ...Using the Recovery Discs 5 50 RTX100A ISDB T RF Signal Generator Service Manual...

Страница 131: ...Options...

Страница 132: ......

Страница 133: ...ides calibration data for 5 years Option C3 Provides calibration services for 3 years Option C5 Provides calibration services for 5 years Option R3 Extends the instrument warranty to 3 years Option R5...

Страница 134: ...Options 6 2 RTX100A ISDB T RF Signal Generator Service Manual...

Страница 135: ...Diagrams...

Страница 136: ......

Страница 137: ...ms This section contains the following diagrams H Block diagram of the RTX100A H Interconnect diagram of the RTX100A Block diagrams show the modules and functional blocks in the RTX100A Interconnect d...

Страница 138: ...Diagrams 7 2 RTX100A ISDB T RF Signal Generator Service Manual...

Страница 139: ...A30 LCD Display AC Distributer Board A40 5 V Sub Power Supply Inverter USB USB Com LAN VGA Disk I F Board A50 DVD Drive Hard Disk Drive Card Edge Card Edge Card Edge SPI In Out Trig In Out Clock Ref...

Страница 140: ...7 4 RTX100A ISDB T RF Signal Generator Service Manual...

Страница 141: ...CN5 CN6 CN9 CN14 J230 J310 J290 J150 J110 J120 J100 J120 J100 J110 J100 J120 CN3 CN4 CN1 IEEE1394b CN2 J100 CN7 J100 174 B924 00 119 7187 00 119 7186 00 174 5187 00 174 5183 00 J200 174 5181 00 174 5...

Страница 142: ...7 6 RTX100A ISDB T RF Signal Generator Service Manual...

Страница 143: ...Replaceable Parts List...

Страница 144: ......

Страница 145: ...serial number H Instrument modification number if applicable If you order a part that has been replaced with a different or improved part your local Tektronix field office or representative will conta...

Страница 146: ...e this list to identify and order replacement parts The following table describes each column in the parts list Parts list column descriptions Column Column name Description 1 Figure Index Number Item...

Страница 147: ...e parts list Manufacturers cross index Mfr code Manufacturer Address City state zip code S3109 FELLER 72 VERONICA AVE UNIT 4 SUMMERSET NJ 08873 TK2432 UNION ELECTRIC 15 F 1 FU SHING N ROAD TAIPEI TAIW...

Страница 148: ...G 0 050 AL SILVER GRAY W FEET HANDLE SAFETY CONTROLLED 80009 4 211 0711 00 2 SCR ASSEM WSHR 6 32X0 250 PNH STL CDPL T 15 TORX DR MACHINE W SQ CONE WASHER 80009 5 335 1374 00 1 MARKER IDENT LABEL MKD W...

Страница 149: ...Replaceable Parts List RTX100A ISDB T RF Signal Generator Service Manual 8 5 4 2 6 3 7 1 8 5 Figure 8 1 Cabinet and covers...

Страница 150: ...A OUT LEA150F 12 R COSEL 80009 13 211 0711 00 1 SCR ASSEM WSHR 6 32X0 250 PNH STL CDPL T 15 TORX DR MACHINE W SQ CONE WASHER 80009 14 196 3496 00 1 LEAD ELECTRICAL 18 AWG 4 0 L 5 4 SAFETY CON TROLLED...

Страница 151: ...rator Service Manual 8 7 4 DVD drive See Figure 8 5 on page 8 12 for detailed view 16 10 9 7 1 A40 6 13 Front panel unit See Figure 8 4 on page 8 11 for detailed view 2 5 8 12 11 24 27 28 25 26 15 14...

Страница 152: ...WIRED 80009 6 174 5190 00 1 CABLE ASSEMBLY 28AWG FLAT 1 27CTR W CONN D SUB25 2X13 80009 7 210 0054 00 2 WASHER LOCK 4 SPLIT 0 025 THK STL CD PL 80009 8 214 3903 01 2 SCREW JACK 4 40X0 312 EXT THD 4 40...

Страница 153: ...Replaceable Parts List RTX100A ISDB T RF Signal Generator Service Manual 8 9 10 9 6 1 2 3 5 7 8 11 4 12 13 15 14 16 A12 A20 A150 Figure 8 3 Internal modules 2...

Страница 154: ...ACKING LCD REAR PORYCARBONATE SHEET T0 5 80009 6 259 A002 01 1 FLEX CIRCUIT A60 LCD I F 80009 7 407 5048 00 1 BRACKET ASSY FRONT COVER STL SST MTX100 80009 8 366 A046 00 1 PUSH BUTTON POWER SILVER GRA...

Страница 155: ...Replaceable Parts List RTX100A ISDB T RF Signal Generator Service Manual 8 11 1 3 2 4 5 6 7 8 9 11 10 A35 12 A30 13 14 15 Figure 8 4 Front panel unit...

Страница 156: ...7123 00 1 DISK DRIVE OPTICAL CD RW DVD R RW DVD R RW 16 7 MB SEC 650MEG 8 5GIG IDE ATAPI TEAC MODEL DV W28E 793 80009 2 671 5980 XX 1 CIRCUIT BD ASSY A50 DISK I F 389 3739 00 WIRED 80009 3 211 0373 00...

Страница 157: ...TY CONTROLLED 80009 9 174 B924 00 1 CABLE ASSEMBLY SP ELEC 80 30AWG 5CM L FLAT W CONN YAMAICHI 80009 10 174 5190 00 1 CABLE ASSEMBLY 28AWG FLAT 1 27CTR W CONN D SUB25 2X13 DSUB25 CPU 80009 11 174 5186...

Страница 158: ...Replaceable Parts List 8 14 RTX100A ISDB T RF Signal Generator Service Manual 2 3 5 4 6 8 7 17 16 18 10 14 11 15 19 1 12 A60 Power supply Hard disk drive Fan 13 9 Figure 8 6 Cables...

Страница 159: ...W TAPE TV GRAY 80009 161 0066 00 1 CABLE ASSY PWR 3 18 AWG 250V 10A 98 0 L STR IEC320 RCPT X NEMA 5 15P US SAFETY CONTROLLED S3109 161 0066 09 1 CABLE ASSY PWR 3 0 75MM SQ 250V 10A 99 0 L STR IEC320 R...

Страница 160: ...Replaceable Parts List 8 16 RTX100A ISDB T RF Signal Generator Service Manual...

Отзывы: