5. Transfer the mounting hole locations to the floor with a marker.
6. Remove the mounting brackets and also mark the location of the cabinet leveling legs.
7. Lower the cabinet and move as needed for drilling and installing the customer supplied floor anchors.
Anchors should have a minimum pullout rating of 1000 pounds each (450 Kg). Install 16 anchors for maximum
protection.
8. Return the cabinet to marked locations on the floor and lift the cabinet with leveling legs to the proper height.
9. Attach the mounting brackets to the corners with the mounting hardware provided (16 screws and washers).
10. Fasten brackets to the floor with the washers and at minimum grade five bolts (these are customer
supplied)(see next figure).
The next figure shows how a floor mounting bracket is installed. Keithley part numbers are included for the required
hardware.
Figure 31: S500 advanced cabinet floor mount