APPENDIX
173
A
PPENDIX
2260B Default Settings
The following default settings are the factory configuration settings
for the power supply (Function settings/Test settings).
For details on how to return to the factory default settings, see page
56.
Initial Settings
Default Setting
Output
Off
LOCK
0 (Disabled)
Voltage
0V
Current
0A
OVP
Maximum
OCP
Maximum
Normal Function
Settings
Setting Default Setting
Output ON delay time
F-01
0.00s
Output OFF delay time F-02
0.00s
V-I mode slew rate select F-03
0 = CV high speed priority
Rising voltage slew rate F-04
60.00V/s (2260B-30-XX)
160.0V/s (2260B-80-XX)
500.0V/s (2260B-250-XX)
1600V/s (2260B-800-XX)
Falling voltage slew rate F-05
60.00V/s (2260B-30-XX)
160.0V/s (2260B-80-XX)
500.0V/s (2260B-250-XX)
1600V/s (2260B-800-XX)
Содержание Keithley 2260B Series
Страница 5: ...Series 2260B Multi Range Programmable DC Power Supplies USER MANUAL ISO 9001 CERTIFIED MANUFACTURER ...
Страница 14: ...2260B Series User Manual 10 Considerations 33 Grounding 36 ...
Страница 43: ...OPERATION 39 Remove Test Sequence 99 Test Sequence Error Messages 100 ...
Страница 52: ...2260B Series User Manual 48 Removal Reverse the procedure to remove the terminal covers ...
Страница 111: ...CONFIGURATION 107 Note Power On and Calibration settings can only be set during power up ...