Connecting the sensor tip cables
Tektronix provides different types of sensor tip cables to connect to the circuit board.
The MMCX sensor tip series connect directly to MMCX connectors on the circuit board or to probe tip adapters installed on
the circuit board.
Installing the probe tip adapters
on page 41
The square pin series sensor tip cables connect directly to the circuit board as shown in the following figure.
Figure 14: Square pin series sensor tip cables
The SQPIN series sensor tip cables connect to 0.1-inch (2.54 mm) square pins on the circuit board. The WSQPIN series
sensor tip cables connect to 0.2-inch (5.08 mm) square pins on the circuit board.
Probe tip tripod
Use the probe tip tripod to connect the sensor tip cables to adapters on the circuit board. This tripod has flexible hinges to
easily position the probe tip cable above the adapter on the circuit board. Tektronix recommends gluing the tripod in place
on the circuit board to provide additional support for the sensor tip cables. The following figure shows an example of
connecting to an adapter on the circuit board with the tripod; it reduces stresses on the test point.
Figure 15: Connecting to an adapter on the circuit board with the probe tip tripod
Installing the probe tip adapters
Tektronix provides two probe tip adapters to connect the MMCX sensor tip cables to pins on the circuit board. The MMCX-
to-0.1-inch (2.54 mm) pitch adapter and the MMCX-to-0.062-inch (1.57 mm) pitch adapter.
One end of each adapter has an MMCX socket for connection to an IsoVu MMCX tip cable. The other end of the adapter
has a center pin socket and four common (shield) sockets around the outside of the adapter. Notches on the adapters can
be used to locate the shield sockets. The procedure for installing these adapters are the same, the main difference is the
spacing of the pins on the circuit board.
To install the adapters onto the square pins, line up the center of the adapter with the signal source pin on the circuit board.
Use the notch on the adapter to align one of the shield sockets to the common pin on the circuit board. The following figures
show examples of lining up the adapters on the circuit board.