Operating Instructions
—DC
502
Contact
28B
27A
27B
26A
25A
25B
24B
23B
22B
20B
20A
21B
19A
19B
Assignment
Second decimal point (D2) output.
Internal
scan
clock disable input.
MHz
light output.
Reset
input/output.
TS0 (Time Slot Zero)
output.
External
scan clock input.
Internal
scan clock (2 kHz) output.
Overflow
output.
MSD
(Most Significant Digit) output.
8
4
2
1
BCD
output,
serial by digit.
Data good output.
Fig. 1-3. Input/Output pin assignments
at rear
connector.
Rear
Connector
I/O Assignments
Input and
output
data
access to
the DC 502 is available
at the
rear
of
the main
circuit board. Fig. 1-3 identifies the
contacts
and
their
respective I/O
assignments. A Power
Module
mainframe option is available
which
provides a
rear-panel,
multi-pin connector to which these data can be
hard-wired for external
access. Also possible are intra
compartment
connections with other plug-in modules when
using
a
multi-compartment Power Module.
SPECIFICATIONS
Option
1—Precision Time
Base
The
DC
502 can be ordered with a temperature-
compensated
5-MHz
crystal
oscillator to provide a
highly
stable
(5
parts in 107 ) and precise internal time base. This
option
includes
a divide-by-five 1C counter to produce the
1-MHz
clock.
Measurement
Ranges, Resolution, and
Accuracy
Frequency,
10
Hz to 550 MHz; Gate times, 0.01 s, 0.1 s,
1
s,
and 10 s; Display time, about 0.1
s to 10 s to HOLD;
Totalizing
capacity, 0 to 107;
Resolution (DIRECT
INPUT), 100
Hz
at 0.01 s gate time, 10 Hz at 0.1 s, 1 Hz at
1
s, and
0.1 Hz
at
10 s; Resolution (4-10
PRE-SCALE
INPUT),
1000 Hz
at 0.01 s, 100 Hz at 0.1 s, 10 Hz at
1 s,
and
1 Hz
at 10 s; Accuracy, ±1 count ± time base accuracy.
Direct
Input
Frequency,
10
Hz to 110 MHz;
Sensitivity,
300
mV
peak-to-peak;
Trigger
level
range,
±2
V;
Attenuators,
X1,
X5, X10,
and X50;
Coupling,
AC;
Input
impedance,
approximately
1 MΩ paralleled by
about 20 pF;
Maximum
input
volts,
500
V
(DC + peak AC, or peak-to-peak AC).
÷10
Pre-Scale
Input
Frequency,
50
MHz to 550 MHz;
Sensitivity,
500
mV
peak
to
peak;
Coupling,
AC;
Input
impedance,
approxi
mately 50
Ω;
Maximum
input
volts,
10
V peak-to-peak.
Data
Inputs and Outputs
Available
via plug-in connector to multi-pin connector at
rear
of Power Module. Input lines are available for internal
and
external
scan clock
control. Output lines are available
for
BCD output (serial-by-digit),
and to indicate
status of
timing, data
good, reset,
scale, decimal point and overflow.
Internal Time
Base
Standard
Option
1
Crystal
Frequency
1
MHz
5
MHz
Stability
(0°C to
+50°C),
after
1/2
hour warm-up
Within 1 part
in
10
5
Within
5 parts in
10
7
Long-term
Drift
1
part or less in
105 per month
1
part in
107 per
month
Accuracy
Adjustable
to
within
1 part
in
107
Adjustable
to
within 5 parts
in
109
Other
Temperature
Range,
Operating: 0°C
to +50°C; Non
operating:
—40°C to +75°C.
Altitude
Range,
Operating:
to 15,000
feet; Non- )
operating: 50,000
feet.