Basic Test Procedures
CTS850 SDH/PDH Test Set User Manual
3–21
Multiplexer Section, Path, or Payload errors by pressing the
buttons corresponding to those choices.
5. To see network performance data since the start of the test
presented in graphical form, change the CTS850 setup as follows:
Press Menu
Button
Select Menu
Page
Highlight
Parameter
Select Choice
RESULTS
HISTORY
GRAPHS
none
none
6. The CTS850 history coverage is based on storage interval which
is determined by TEST SETUP. You can choose history graphs of
the measured performance indicators in the following categories:
H
Error count (any error you choose)
H
Errored seconds (any error you choose)
H
Pointer justifications
H
Pointer value
H
All failures
H
All alarms