Other conditions
Other conditions
Other conditions
Other conditions
Dielectric constant (
ε
r
)
Level in direct mode:
Level in direct mode:
Level in direct mode:
Level in direct mode:
≥
1.4 for coaxial probe;
≥
1.6 for single and double probes
Interface in direct mode:
Interface in direct mode:
Interface in direct mode:
Interface in direct mode:
ε
r
(interface) >>
ε
r
(level)
²
Level in TBF mode:
Level in TBF mode:
Level in TBF mode:
Level in TBF mode:
≥
1.1
Vibration resistance
IEC 60068-2-6 and EN 50178 (10...57 Hz: 0.075 mm / 57...150 Hz:1g)
Protection category
IP 66/67 equivalent to NEMA 4X (housing) and 6P (probe)
Installation conditions
Process connection size
Refer to "Installation: How to prepare the tank before you install the device" and
"Technical data: Measurement limits"
Process connection position
Make sure that there are not any obstructions directly below the process
connection for the device.
Dimensions and weights
Refer to "Technical data: Dimensions and weights"
Material
Housing
Standard: Polyester-coated aluminium
Option: Stainless steel (1.4404 / 316L)
3
Single rod (single-piece)
Standard: Stainless steel (1.4404 / 316L)
Option: Stainless steel (1.4404 / 316L) in a PVDF protective sheath, HASTELLOY
®
C-
22
®
(2.4602)
4
On request: Stainless steel (1.4404 / 316L) in a PVC or PP protective sheath
On request: Monel; Tantalum; Titanium; Duplex
Single rod (segmented)
Standard: Stainless steel (1.4404 / 316L)
Coaxial (single-piece)
Standard: Stainless steel (1.4404 / 316L)
Option: HASTELLOY
®
C-22
®
(2.4602)
Single cable
Standard: Stainless steel (1.4401 / 316)
Option: HASTELLOY
®
C-22
®
(2.4602)
–
only for the Ø2 mm / 0.08
¨
single cable probe
On request: FEP-coated stainless steel (-20...+150
°
C / -4...+302
°
F)
–
only for the Ø4 mm / 0.16
¨
single cable probe
Process fitting
Standard: Stainless steel (1.4404 / 316L)
Option: HASTELLOY
®
C-22
®
(2.4602)
On request: Monel; Tantalum; Titanium; Duplex
Gaskets
FKM/FPM (-40
…
+200
°
C / -40
…
+392
°
F); Kalrez
®
6375 (-20
…
+200
°
C / -4
…
+392
°
F);
Weather protection (Option)
Stainless steel (1.4301 / 304)
Protective sheath
(On request for single rod only)
PP (-40
…
+90
°
C / -40
…
+194
°
F); PVC (-15
…
+80
°
C / +5
…
+176
°
F);
PVDF (-40
…
+150
°
C / -40
…
+302
°
F)
Conduit for remote housing
(Option)
Zinc-coated steel in a PVC sheath (-40...+105
°
C / -40...+221
°
F)
Technology Solutions
Instruction Manual
Tek-Flex
4100A
www.tek-trol.com
1
19