ATTACHING INCOMING AIR
For consistent leak-free performance, air inlet is made of solid brass. Brass is a soft metal and extra care should be taken to
avoid cross threading. For a tight, leak-free connection, follow all instructions carefully.
Option 1
Wrap incoming air hose end with thread sealing tape. Thread air hose end into air inlet, taking care not to cross thread.
Tighten connection with wrench. Do not over-tighten.
Option 2
Locate included swivel nut connector. Wrap threaded end with thread sealing tape. Thread into air inlet, taking care not to
cross thread. Tighten connection with wrench. Do not over-tighten. Next, wrap end of incoming air hose with thread sealing
tape. Thread air hose into swivel end of connector, by turning swivel collar. Tighten connection with wrench. Do not
over-tighten.
To ensure optimum performance, check all connections for leaks. With air system pressurized, brush each
connection with soapy water. Inspect closely. Air bubbles indicate leaking air. Tighten any leaking fittings.
OPTION 2
OPTION 1
Lead-in
Hose
Lead-in
Hose
Swivel Nut
Connector
page 10