Do not allow any foreign matter such as metal or inflammable substance to get into the instrument 

via the air holes. The penetration of any foreign matter from the ventilation holes could result in fire, 

electrical shock, or power failure. 

z

 

Use this instrument with the rated AC power sources. Use of this instrument with a voltage other 

than specified could result in electrical shock, fire or power failure. The usable power voltage range 

is marked on the rear panel. 

z

 

Do not remove either the cover or panel. 

z

 

Do not modify this instrument. 

z

 

Avoid use of damaged cables. 

 

 

1.1 BEFORE USE 

1.  Make sure the POWER switch is at the “0” position and connect the power cord to the power supply. 

2.  To set the constant voltage output: Push the 

POWER SWITCH

 to “I” position. Adjust the 

VOLTAGE 

COARSE

 / 

CURRENT COARSE

 tune knob for roughly adjustment or 

VOLTAGE FINE

 / 

CURRENT

 

FINE

 tune knob for fine adjustment. Once the voltage or current value is reached, to desire value 

appear on 

Display Panel

 

 

1.2 DURING USE 

1.  Ensure the voltage and current set to zero, prevent a undesired output damage the circuit. 

2.  The supplied voltage should be within 110V AC or 220V AC

±

10% (60/50Hz) and the system is 

capable for supplying the maximum power consumption as indicated on

 

section 3.1. 

3.  Keep a distance at least greater than 10cm between the power supply and other things for airy 

reason when usage. Do not place this power supply in a hot, dusty, wet, corrosive gas stage or near 

the poison substance.  

4.  This power supply need warm up 30 minutes to meet the specification section 3.2. 

5.  Keep hands and face away from the heat sink. 

6.  Do not touch the heat sink during operation. 

 

1.3 AFTER USE 

1.  Once the operation completed, remove all connection to the power supply, especially the power 

source. 

2.  Wait the power cold down. 

3.  Store in a dry, well air and non-dusty environment. 

 

 

 

 

Содержание TP-3005D

Страница 1: ...IONS 4 3 1 OPERATION CONDITION 4 3 2 TECHNICAL SPECIFICATION 4 4 OPERATING INSTRUCTIONS 5 4 1 INSTRUMENT DESCRIPTION 5 4 1 1 FRONT PANEL DESCRIPTION 5 4 1 2 REAR PANEL DESCRIPTION 6 5 POWER SUPPLY DES...

Страница 2: ...z For your own safety and that of the instrument you must follow the procedure described in this instruction manual z Do not use this instrument in a location where there is explosive gas in the vicin...

Страница 3: ...ghly adjustment or VOLTAGE FINE CURRENT FINE tune knob for fine adjustment Once the voltage or current value is reached to desire value appear on Display Panel 1 2 DURING USE 1 Ensure the voltage and...

Страница 4: ...0V AC or 220V AC 10 60 50Hz Power Consumption 300W Operating Condition Temperature 0 40 Relative Humidity 90 RH Storage Condition Temperature 20 80 Relative Humidity 80 RH Non condensing 3 2 TECHNICAL...

Страница 5: ...R When the power supply is at the constant current mode this LED light will be on 5 CV constant voltage mode INDICATOR When the power supply is at the constant voltage mode this LED light will be on 6...

Страница 6: ...t value 12 main positive terminal 0 30V positive output 13 GND grounding terminal This terminal is connecting to the casing and the Earth 14 main negative terminal 0 30V negative output 15 USB output...

Страница 7: ...E COARSE TUNE KNOB 8 and VOLTAGE FINE TUNE KNOB 9 to adjust and fine turn the voltage to give a desired output voltage 5 Connect the circuit to the MAIN TERMINAL 12 14 6 When the CC INDICATOR 4 is on...

Страница 8: ...INDICATOR 5 will off and the CC INDICATOR 4 will on 6 Adjust the CURRENT KNOB 10 11 to give a desired output current 7 Repress the ACCIDENTAL PROTECTION KEY 2 to cut off the output 8 Then the CC INDIC...

Страница 9: ...clockwise to open the fuse socket 5 Replace the fuse with identical rating Rating see section 4 1 1 6 Use the cross screw drive and turn clockwise to close the fuse socket Caution z Ensure no power i...

Страница 10: ...ical rating fuse When operate in CV mode the voltage drop down and the CC indicator on It is the current protect The desired current range is under the circuit gain The power supply switched to CC mod...

Отзывы: