Troubleshooting
Phenomenon
Troubleshooting
Immediately stop all operations and plug out, contact
Indoor unit cannot deliver air
In HEAT mode, when the temperature of
the dealer in following situations.
indoor heat exchanger is very low, that will
stop deliver air in order to prevent coolair.
(Within 3min)
In HEAT mode, when the outdoor tempera-
ture is low or high humidity, there are much
frost be formed
on the outdoor heat
exchanger, that the unit will automatically
defrost, indoor unit stop blowing air for 8-
10min.During the defrosting,there is water
flowing out or vapor be produced.
In dehumidifying mode, sometimes fan will
stop, in order to avoid condensing water be
vaporized again, restrain temperature rising.
- The air humidity is on the high side.
- Condensing water overflowed.
- The connection position of indoor unit
drainage pipe is loosed.
- The sound of fan or compressor relay is
switching on or off.
- When the defrosting is started or stop
running, it will sound. That is due to the
refrigerant flowed
If unit is running under the high humidity fora
long time, the moisture will be condensedon
the air outlet grill and drip off.
Noise from indoor unit emitted.
Noise from indoor unit emitted.
If water leakage in the room
Moisture on air outlet vent
There is harsh sound during operation
The terrible odors emitted during operation
Water is leaking in the room
Air switch or protection switch often breaks
Carelessy splash water or something into unit
There is an abnormal heat in power supply cord
Stop running and pull out of the plug.
and power plug.
40
Содержание DKV Series
Страница 1: ...Climatizzatore Monosplit Monosplit airconditioner Manuale installatore Installation manual DKV Series...
Страница 3: ...ITALIANO...
Страница 17: ...INSTALLAZIONE 17...
Страница 25: ...ENGLISH 25...
Страница 41: ...INSTALLATION 41...
Страница 48: ...TEKNO POINT www teknopoint com tecnico teknopoint com klima teknopoint com...