TEK
NİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
33 / 81
PS:
Days of the week are; 1: Sunday 2: Monday 3: Tuesday 4: Wednesday 5: Thursday 6: Friday
7: Saturday.
Timer 2 Time
This setting determines the days that PGM will be activated.
•
LED Keypad;
[14] [06]
→
[
HH:MM
]
→
[
√
OK]
•
LCD Keypad;
[Panel Settings
√
OK]
→
[Timer Settings
√
OK]
→
[Timer 2 Time
HH:MM
]
→
[√
OK]
7.4.6
Remote Access
This section contains settings for remote control of the alarm panel by phone and settings for usage
of the Cloud Communication.
Remote Control Settings
Use the option 1 to turn on or off remote alarm panel access by phone. And option 2 to open or close
the Cloud communication.
•
LED Keypad;
[15] [01]
→
[
1-2
]
→
[√
OK]
•
LCD Keypad;
[Panel Settings
√
OK]
→
[Remote Access
√
OK]
→
[Rem. Cont. Sett.
1-2
]
→
[√
OK]
Ring Count
It determines ring numbers after control panel response by remote control with Phone.
•
LED Keypad;
[15] [02]
→
[
X
]
→
[
√
OK]
•
LCD Keypad;
[Panel Settings
√
OK]
→
[Remote Access
√
OK]
→
[Ring Count Time
X
]
→
[√
OK]
7.4.7
Panel Info
This is where you can access basic information about the alarm panel. No settings can be made in
this section, only readable information.
Basic Informations are;
Panel Type, Software Version, Hardware Version.
•
LED Keypad;
[16] [01]
→
[Panel Type]
→
[
√
OK]
[16] [02]
→
[SW Version]
→
[√
OK]
[16] [03]
→
[HW Version]
→
[
√
OK]
•
LCD Keypad;
[Panel Settings
√
OK]
→
[Panel Info
√
Ok]
→
[Panel Type]
→
[√
OK]
[Panel Settings
√
OK]
→
[Panel Info
√
Ok]
→
[SW Version]
→
[√
OK]
[Panel Settings
√
OK]
→
[Panel Info
√
Ok]
→
[HW Version]
→
[√
OK]
Option
1.
2.
Feature
Access by Phone
Cloud Connection
LED ON
Yes
Active
LED OFF
NO
Passive