NİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
17 / 81
IMPORTANT:
The total length of the connecting cable between the keypad and the panel can be
up to 100 meters
Keypad Zone Connection;
6.6
COMMUNICATION MODULE CONNECTIONS
6.6.1
Telephone Line Connection (For TSP-5314 Panel)
The telephone line connection of the panel is made with
LINE
terminal group. An internal or external line can be used in the
connection. If the line is disconnected, an error message is
displayed. Trouble and Memory lights flash on
LED
Keypad. The
Trouble
light on the LCD Keypad turns on and the display shows
an error message. Error message disappears when panel
detects line. Also, a parallel device must not be connected to the
line at the
LINE
input. If there is a single telephone line and other
devices will use this line, the
PTT
line must be connected to the
LINE
input and the line must be continued from
PHONE
output to
other devices (Telephone, Fax, POS machine, etc.).
PS:
If the ADSL line is used, the telephone line connection of the panel must be made through the
phone line output of the SPLITTER device. Otherwise, the phone call feature of the panel may be
adversely affected.
Figure 13:
Keypad Connection
Figure 14:
Phone Line Connection
Phone Line
Figure 14:
Keypad Zone Connection
MAG
GND
12V
A
B
GND