TEK
NİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
22 / 81
7.2 ENTERING-EXITING INSTALLER PROGRAM AND MASTER PROGRAM
To enter the engineering program, press [Fx] then [4], a long beep sounds and enter the engineer
password.
The device enters the “
Installer Program
”
. Program LED on LED Keypad, Ready light
flashes. LCD keypads display "INSTALLER MENU".
To enter the Installer Program;
Press [Fx] then Press [4] enter Installer Code (
XXXX
)
Factory Default of Installer Code is = 9999
To enter the master program, press [Fx] then [4], a long beep sounds and enter the master code. The
device enters the “
Master Program
”
. Program LED on LED Keypad, Ready light flashes. LCD keypads
display "MASTER MENU".
To enter the Master Program;
Press [Fx] then Press [4] enter Master Code (
XXXX
)
Factory Default of Master Code is = 1234
To exit the program, hold down the
X (Exit)
key until a long beep sounds and the device returns to
normal.
Program
LED off.
PS:
If no commands are sent to the panel within 3 minutes after programming, the panel
automatica
lly exits the “Program” position and re
turns to normal.
7.3
BASIC SETTINGS
This is the section where the basic settings such as date - time, delay times and telephone numbers
are made.
7.3.1
Time/Date Settings
The Control Panel's Time and Date settings are made in this step, a panel without a time and date
setting turns on the Trouble LED and gives an error warning. Error settings are automatically
removed when these settings are made.
Setting the Time
•
LED Keypad;
[01] [01]
→
[
HH: MM
]
→
[
√
OK]
•
LCD Keypad;
[Basic Settings
√
OK]
→
[Time/Date Settings
√
OK]
→
[
HH: MM
]
→
[
√
OK]
eg.
To set time 09:05 with LED Keypad;
[01] [01
] [09] [05] [√
OK]
Setting the Date
•
LED Keypad;
[01] [02]
→
[
DD:MM:YY
]
→
[
√
OK]
•
LCD Keypad;
[Basic Settings
√
OK]
→
[Time/Date Settings
√
OK]
→
[
DD:MM:YY
]
→
[
√
OK]
eg.
To set date 10.11.2019 with LED Keypad;
[01] [02]
[10] [11] [19] [√
OK]