1.
Select the motor of interest from the Motor List (It should appear
under the "Rear USB: ONLINE" heading in the UI.
2.
Set the access level from the Access menu in ClearView. Users
primarily use Monitor Mode or Tune Mode. Note: Access modes
are explained below.
A
CCESS
M
ODES
E
XPLAINED
Monitor Mode
ClearView allows the Diagnostic Channel to access the Soft Scope.
ClearView restricts Diagnostic Channel access to most other settings and
parameters (restricted items will be grayed out in the UI). The Application
Channel has "full access" in this mode.
Tune Mode
ClearView allows the Diagnostic Channel to access the Soft Scope and
most of the tuning gains, RAS, and g-Stop settings, tracking error limit,
and fine tuning controls. The Application Channel has "full access" in this
mode.
Full Access Mode
The Diagnostic Channel has full control of the motor, including access to
all normally available settings and parameters. The Application Channel