Input A
Input B
Axis 0
Schematic snippet: Input A and B
M
INIMUM
C
URRENT
R
EQUIREMENT
Input devices wired to ClearPath-SC inputs must be able to source/sink a
minimum of 12mA.
Engineer’s Note: In all ClearPath-SC motors, the logic-level signals are
electrically isolated from the DC power input and motor output circuits, as
well as from the motor case to ensures that control signals are not
compromised by induced currents from the motor, power supply, or PWM
return path.