C
L E A R
P
A T H
- S C
U
S E R
M
A N U A L
R
E V
.
1 . 3 6
3 3
T
EKNIC
,
I
NC
. T
EL
.
(585)
784-7454
D
IRECT
P
OWER
C
ONNECTION
One or two motors can be connected directly to the IPC-3 or IPC-5 power
supply as shown below. To connect more than two motors, consider using
a Power Hub (next page) or chaining power as shown below.
75VDC
(Bus In)
75VDC
(Bus In)
ClearPath-SC Motors
I
PC-5
75VDC
Bus Supply
75VDC
Bus Out
AC Source
110/220VAC
ClearPath-SC direct DC bus power connection
P
OWER
C
HAINING
M
ULTIPLE
M
OTORS
For applications with several ClearPath motors, daisy chaining power
from motor to motor (see figure below) may be preferable.
Power Supply
(IPC-5 shown)
ClearPath-SC Motors
2. GND
1. V+
4. GND
3. V+
Connector Housing
4 pos.
Molex/39-03-9042 (black)
Terminals
16AWG
Molex/39-00-0078 (loose)
Molex/39-00-0077 (reel)
Crimp Tool
16-24 AWG
Molex/63819-0900
Terminal Extractor Tool
Molex/11-03-0044
Mating Parts
Cable Stock
2/16AWG (black)
Belden/9410
Note:
NEMA 34 motors are shown at left. NEMA 23 models have
4-pin and 8-pin connector positions swapped, but pinouts and
signal names are functionally identical for both motor sizes.
Power chaining ClearPath-SC motors