Phase 2 - Fixture Installation (Pole Top Option)
Pole Top Installation Instructions
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
DATE
5-14-18
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.tekaillumination.com • [email protected]
REFERENCE NUMBER
INS-2569-00
BEACON POLE MOUNT™ (BPM)
2. Make watertight connections from primary
branch circuit to driver leads using waterproof
wire connectors (By Others). Connect green
ground wire to ground wiring from driver.
Connect incoming dimming controls to driver
primary side dimming controls. Secondary side
is connected via quick disconnect.
See wiring
diagram.
WIRING DIAGRAM
1. Pull primary branch circuit wiring up to driver
bracket location at top of pole. Pull incoming
dimming controls to top of pole. Feed through
strain relief.
LINE
Red
FIXTURE
COM
Driver
Black
GROUND
DIM +
DIM -
GROUND IN HOUSING
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
GROUND ON PLATE
LINE
Red
FIXTURE
COM
Driver
Black
DIM +
DIM -
3. Place connections and driver on bracket into
pole. Rest bracket on pole top or tenon.
Phase 1 - Install Pole
1. Install 3-1/2” O.D. pole (By Others) or pole with
3-1/2” O.D. tenon (By Others, Specify Separately)
according to lighting plan and manufacturer’s
installation instructions. Install conduit (By
Others) to be used with this product.
2. Pull primary branch circuit wiring necessary for
installation (By Others). Pull incoming dimming
controls necessary for installation. (By Others).
Leave sufficient wire length in the pole for
future service.
4. Slide fixture over pole top. Secure with four (4)
1/4-20 screws using /1/8” Allen wrench. Make
sure the fixture is completely seated. Do not
overtighten.
4. Make secondary connections via quick disconnect
from driver secondary side to fixture secondary
side.