5.1.1 Positioning the perforated sheet
If the perforated sheet (see chapter 2.1) is to fulfil its function it must be mounted on the exhaust air
side, i.e. on the side on which the exhaust air nozzle is located (see section 2.1). Before taking the
equipment into service, it is therefore necessary to check that the perforated sheet is mounted on the
correct side.
●
Open the service door (see chapter 2.1).
●
If this has not already been done, position the perforated sheet on the exhaust air side. Push
the perforated sheet fully into the guide.
Make sure that the handle is at the front.
5.2 Electrical connection
WARNING
Risk of electric shock.
Electrical plants and equipment may only be built, modified and maintained by a qualified
electrician or under the direction and supervision of a qualified electrician. Do not work on
live electrical components and elements if you are not sure that these are indeed
disconnected. If necessary, disconnect the device from the mains. The operator is
responsible for a potential-free balance of the equipment.
NOTICE
Electric malfunction possible in cause of an incorrect power supply.
Pay attention to the admissible supply voltage. Please observe the specifications on the type
plate.
●
Connect the mains cable (see chapter 2.1) to the power supply.
BA_Funkenvorabscheider_171107_EN