12 Maintenance intervals
12.1 Usage-related maintenance
The described maintenances become necessary through the demands of the system operations. The
maintenance intervals are recommendations. Depending on the application (multi-shift operation, dust
generation, ...) it may make sense for the operator to change the intervals of maintenance, replacing
and cleaning.
Maintenance work must always be documented by means of a protocol.
The approach of the maintenance measures is described in chapter "Maintenance".
Maintenance work
Chapter
Maintenance interval
recommended by TEKA
determined by the operator
Cleaning the dust collecting tank (or
check of fill level)
7.2
weekly
Cleaning of the spark separator
7.3
monthly
Maintenance of the filling level
sensors
7.4
monthly
12.2 General maintenance
The described maintenances are independent from the demands of the system operations.
The operator is obliged to carry out repeated inspections and functional tests according to national
regulations. If not otherwise covered by national regulations, the described maintenance intervals must
be respected.
Maintenance work must always be documented by means of a protocol.
Maintenance work
Chapter Maintenance interval
Visual
inspection of the device
12.2.1
weekly
Visual
inspection of the pipelines for dust deposits
12.2.2
monthly
Electrical
test of the electrical lines and earthing connections
12.2.3
annually
BA_Funkenvorabscheider_171107_EN
17
11.01.2022