58
1-06
Middle Output Frequency (Hz)
0.1~ 400.0
1.5
1-07
Voltage at Middle Output Frequency (V)
0.1~ 255.0
7.9
1-08
Minimum Output Frequency (Hz)
0.1~ 400.0
1.5
1-09
Voltage at Minimum Output Frequency (V)
0.1~ 255.0
7.9
1-10
Frequency Reference Upper Limit
0~ 109
%
100
%
*
1-11
Frequency Reference Lower Limit
0~ 109
%
0
%
*
1-12
Accelerating Time 1
0.0~ 999.9s
10.0s(
☆
)
1-13
Decelerating Time 1
0.0~ 999.9s
10.0s(
☆
)
1-14
Accelerating Time 2
0.0~ 999.9s
10.0s(
☆
)
1-15
Decelerating Time 2
0.0~ 999.9s
10.0s(
☆
)
1-16
JOG Frequency Reference
0.0~ 400.0Hz
6.0Hz(
☆
)
1-17
S-curve Time at the Starting of Acceleration
0.0~ 1.0s
0.0s
1-18
S-curve Time at the Ending of Acceleration
0.0~ 1.0s
0.0s
1-19
S-curve Time at the Starting of Deceleration
0.0~ 1.0s
0.0s
1-20
S-curve Time at the Ending of Deceleration
0.0~ 1.0s
0.0s
*: The setting value of 1-10 must
≧
1-11.
2- Operating Method Parameters (RUN Command and Frequency Reference Source)
No.
Parameter Name & Description
Setting Range
Default
User set
2-01
Run Command Source Selection:
0- Operator
2- RS-485 Modbus
1- Control Terminals
0
2-02
Frequency Reference Source Selection:
0- Operator
2- RS-485 Modbus
1- Control Terminal- AIN
3-Reference POT of Operator
0
2-03
Stop Method Selection:
0- Decelerating to Stop
1-Coast to Stop (Free Run)
0
2-04
Function of STOP key at OP Selection:
0- STOP Key is enabled
1- STOP Key is disabled
0
2-05
Reverse Command or/ and Reference prohibits:
0- REV is effectual
1- REV is invalid
0
2-06
Carrier Frequency (= Set Value × 2.5kHz)
1~ 6
4
2-07
FRQ REF Hold Selection of
MOP
Control by Multi-function DIns
(Parameter 4-08= 24) when F8 stops.
0- FRQ REF Hold during MOP operation is not retained. If a stop
command is given the FRQ REF will reset to 0Hz. The F8 start to run
from FRQ REF Lower Limit (1-11) if Run Command is given next time.
1- FRQ REF Hold during MOP operation is retained. If a stop command is
given the FRQ REF resumes at the Held FRQ REF when Run command
is restored.
1
2-08
Selects whether the
key is used when the FRQ REF is set by the OP.
The OP can simulate a MOP by setting this PRMs.
0- The OP MOP mode is disabled. The F8 accepts the FRQ REF when the
Key is depressed.
1- The OP MOP mode is enabled. The F8 accepts the FRQ REF as soon as
changes are made with the
&
Keys, without the
Key being
depressed.
0
Содержание TDS-F8
Страница 13: ...11 1 7 基本配線 圖 1 3 變頻器標準配線圖 表示主回路端子 表示控制端子 ...
Страница 22: ...20 3 3 操作器操作 顯示模式說明 一體式操作器 TDS F8 變頻器內含一體式的數位操作器外 其操作方式分別說明如下 A 一體式操作器操作顯示模式 ...
Страница 38: ...36 衰減特性 ...
Страница 39: ...37 6 5 數位操作器安裝尺寸 TMCA V8 LED ...
Страница 40: ...38 TMCA V803 LED 操作器與外拉固定框尺寸 TMCA V803 LED 外拉固定框 75 4 44 71 4 102 4 21 5 24 98 4 102 4 74 ...
Страница 57: ...55 3 3 Menu Structure for Operators Local Operator LOP Fig 3 3 LOP Screen Structure ...
Страница 72: ...70 6 5 Mounting Dimension of External Remote Operator TMCA V8 LED Dimension ...