DOWN button:
Press this button, if in TEMP SET mode, set the heating temperature to decrease; if
in TIME mode, the ultrasonic working time decreases; if in GEN POWER mode, the ultrasonic power
percentage decreases.
HEAT ON/OFF button:
Wash tank heating start/stop button, press this button, the heating light
is flashing, and the cleaning tank starts heating (When the water temperature in the cleaning tank is
higher than or equal to the set temperature, the heating light is on steady, the cleaning tank is not
heating); press this button again, the Heating lamp is off and the heating stops working.
GEN POWER button:
Press this button, the ultrasonic power percentage display light flashes, it
enters the power percentage setting mode, and then press this key to log out this mode. The percen-
tage of power is 0-100%.
TIME button:
When this button is pressed, the time display light flashes and enters the time setting
mode. Press this button for 3 seconds to enter the time-H setting (the default setting is the min setting),
and then press this button to log out this mode. H mode time range 9H59MIN; MIN mode time range
is 59MIN59S.
TEMP SET button:
Press this button, the temperature display light flashes, it enters the temperature
setting mode, the flashing temperature value is the set temperature, press this button again, log out
this mode, the temperature display light is on steady, during this time the digital tube displays the
current actual temperature. In addition, when a communication failure alarm occurs, pressing this key
will cancel the alarm. Set the temperature range 0-100 degrees.
ALARM light:
When the communication between the control board and the ultrasonic generator
fails, or the cleaner start heating/ultrasonic on without water in the tank, the alarm light flashes, and
the buzzer sounds an alarm at the same time. The percentage of ultrasonic power display indicate an
alarm fault code. The fault code is as follows:
1
2
3
4
5
6
7
Fault code
Fault reason
AL-1
E-10
E-20
E-30
E-40
E-50
E-60
Lack of water alarm
Address 1 Generator Communication Failure
Address 2 Generator Communication Failure
Address 3 Generator Communication Failure
Address 4 Generator Communication Failure
Address 5 Generator Communication Failure
Address 6 Generator Communication Failure
operating instructions