background image

10-

or 

  (pan inversion) mode. Once the mode  has  been  selected,  press  the 

button  to  setup.  Idling  8  seconds  automatically  exit  menu  mode.  Back  to  the  functions 

without any change press 

 button.

    Tilt Inversion

Press the 

 button up to when the 

is shown on the display. Pressing 

button and the display will blink. Use 

 and 

 button to select the 

  (normal) 

or 

  (tilt  inversion)  mode.  Once  the  mode  has  been  selected,  press  the 

button  to  setup.  Idling  8  seconds  automatically  exit  menu  mode.  Back  to  the  functions 

without any change press 

 button.

   

Press  the 

  button  up  to  when  the

is  showing  on  the  display.  Pressing 

 button and the display will blink. Use 

 and 

 button to select the 

(Led on) or 

  (Led off) mode. Once the mode has been selected, press the 

button  to  setup.  Idling  8  seconds  automatically  exit  menu  mode.  Back  to  the  functions 

without any change press 

 button.

   

Press  the 

  button  up  to  when  the

is  showing  on  the  display.  Pressing 

 button and 

  will blink on the display, use 

 and 

 button to adjust 

the  value  from  125  to  255,  press 

  button  to store  and 

  will  blink  on  the 

display,  use 

  and 

  button  to  adjust  the  value  from  125  to  255,  press 

button to store and 

  will blink on the display, use 

 and 

 button to adjust 

the value,  press 

 button  to store. Idling 8  seconds automatically exit menu  mode. 

Back to the functions without any change press 

 button.

It is good for you to install the unit on the floor or under ceiling. Press the 

 button up 

to  when  the 

is  blinking on  the  display.  Use  the 

 button to  change  to the 

mode 

  (display inversion), It will automatically store after 8 seconds. Or press the 

  button  again  return  to  the  mode 

  (display  normal).  To  go  back  to  the 

functions press the

 button.

   

Display normal mode for the fixture putting on the floor.

11-

   

Display inversion mode for the fixture fixing under ceiling.

   

Press  the 

  button  up  to  when  the 

is  blinking  on  the  display.  Pressing 

 button, the unit will focus on tilt 90°, and then the unit will focus on tilt 0°, pan 0°, 

pan 90°, pan 180°, pan 270° in every pressing 

 button. To go back to the functions 

press the

 button again.

   

Press  the 

  button  up  to  when  the 

is  blinking  on  the  display.  Pressing 

 button and the unit will run self-test by built-in program. To go back to the functions 

press the

 button again.

   

Press  the 

  button  up  to  when  the 

is  blinking  on  the  display.  Pressing 

 button and the ambient temperature of lamp will show on the display. To go back to 

the functions press the

 button again.

   

Press  the 

  button  up  to  when  the 

is  blinking  on  the  display.  Pressing 

  button and the  display will show  the  number  of working  hours  of the unit.  To  go 

back to the functions press the

 button again.

Press  the 

  button  up  to  when  the 

is  blinking  on  the  display.  Pressing 

 button and the display will blink. Use 

 and 

 button to select the 

(Lamp  on)  or 

  (Lamp  off)  mode.  Once  the  mode  has  been  selected,  press  the 

  button  to  setup.  Idling  8  seconds  automatically  exit  menu  mode.  Back  to  the 

functions without any change press 

 button.

   

Press  the 

  button  up  to  when  the 

is  blinking  on  the  display.  Pressing 

 button and all channels of the unit will return to their standard position. It will cost 

about 20 seconds and then automatically exit menu mode.

ENTER

MENU

MENU

ENTER

DOWN

UP

ENTER

MENU

Led Display

MENU

ENTER

DOWN

UP

ENTER

MENU

White Balance

MENU

ENTER

DOWN

UP

ENTER

DOWN

UP

ENTER

DOWN

UP

ENTER

MENU

    Display  Inve rsion

MENU

ENTER

ENTER

 MENU

Focus Adjust

MENU

ENTER

ENTER

 MENU

Self-Test

MENU

ENTER

 MENU

Ambient te mperature  of lamp

MENU

ENTER

 MENU

Fix ture  Hours

MENU

ENTER

 MENU

Lamp ON/OFF

MENU

ENTER

DOWN

UP

ENTER

MENU

Rese t

MENU

ENTER

Содержание 85-05275

Страница 1: ...ion Adjustment 5 How To Control The Unit 5 1 Master Slave Built In Preprogrammed Function 5 2 Easy Controller 5 3 DMX Controller 5 4 DMX 512 Configuration 5 5 DMX 512 Connection 6 Troubleshooting 7 Ma...

Страница 2: ...ized technical assistance center Always use the same type spare parts Don t connect the device to any dimmer pack Do not touch any wire during operation as there might be a hazard of electric shock 3...

Страница 3: ...hannel 15 Tilt 16 bit Channel 5 Shutter Shaking Channel 16 Reset Lamp on off Channel 6 Color Channel 17 Red LED Channel 7 No Function Channel 18 Green LED Channel 8 No Function Channel 19 Blue LED Cha...

Страница 4: ...not use the lamp any longer than its specified life 5 Make sure the lamp is located in the center of the reflector for the best spot In case of replacement of the lamp or maintenance do not open the...

Страница 5: ...ode Fixture is placed on the speaker The spot is always projecting to the audience s direction i e in front of the stage Pan movement angle left to right to left 160 Tilt movement angle 90 60 above ho...

Страница 6: ...normal mode for the fixture putting on the floor 11 Display inversion mode for the fixture fixing under ceiling Press the button up to when the is blinking on the display Pressing button the unit will...

Страница 7: ...offset mode use and button up to when the is shown on the display Pressing button and the display will blink Use and button to adjust the gobo home position Once the gobo has been selected press the...

Страница 8: ...control all the other units for Stand by Function and Mode Stand by Blackout the unit Function Strobe 1 Color sync strobe 2 Sync strobe 3 T wo light strobe X Y moving show pattern selection Show 1 Sh...

Страница 9: ...lug it in the DMX output of the last unit 3 Connect the unit together in a daisy chain by XLR plug cable from the output of the unit to the input of the next unit The cable cannot be branched or split...

Страница 10: ...PCB might be out of condition 1 The lamp is not working well Check the main voltage either too high or too low 2 Internal temperature may be too high Check and if necessary replace the fan on the 19...

Страница 11: ...screws E that fix the bridge 4 Change a new belt F Please adjust the tension of the belt properly Note do not fix belt too tight as it is easy to rupture 5 Reverse the procedures from point 3 to 2 21...

Страница 12: ...ulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics a...

Отзывы: