SERVICE INFORMATION 

Warranty 

 

TEGAM, Inc. warrants this product to be free from defects in 

material and workmanship for a period of one year from the 

date of shipment. During this warranty period, if a product 

proves to be defective, TEGAM Inc., at its option, will either 

repair the defective product without charge for parts and 

labor, or exchange any product that proves to be defective. 

 

TEGAM, Inc. warrants the calibration of this product for a 

period of one year from date of shipment. During this period, 

TEGAM, Inc. will recalibrate any product, which does not 

conform to the published accuracy specifications. 

 

In order to exercise this warranty, TEGAM, Inc., must be 

notified of the defective product before the expiration of the 

warranty period. The customer shall be responsible for 

packaging and shipping the product to the designated TEGAM 

service center with shipping charges prepaid. TEGAM Inc. shall 

pay for the return of the product to the customer if the 

shipment is to a location within the country in which the 

TEGAM service center is located. The customer shall be 

responsible for paying all shipping, duties, taxes, and 

additional costs if the product is transported to any other 

locations. Repaired products are warranted for the remaining 

balance of the original warranty, or 90 days, whichever period 

is longer. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание R1L-E2A

Страница 1: ...R MODEL R1L E2A Instruction Manual PN R1L E2A 900 01 Publication Date March 2020 REV G An Agency Related Document Those sections identified as controlled cannot be changed without approval of the Noti...

Страница 2: ...nt manufactures Do not mix fresh batteries with old batteries WARNING To reduce the risk of ignition of a flammable or explosive atmosphere batteries must be changed only in a location known to be non...

Страница 3: ...s AVERTISSEMENT Pour r duire le risque d allumage d une atmosph re inflammable ou explosive les piles doivent tre chang es seulement dans une zone connue pour tre non dangereuse AVERTISSEMENT Quand op...

Страница 4: ...nt 1 2 Figure 1 Front Panel and Controls 1 5 List of Items Furnished 1 6 Storage and Shipping Requirements 1 6 2 PREPARATION FOR USE AND INSTALLATION Unpacking and Inspection 2 1 Preparation for Use 2...

Страница 5: ...value digitally on a liquid crystal display LCD The R1L E2A cycles the current ON and OFF during the measurement During the OFF state thermal and offset voltages occurring in the voltage measurement c...

Страница 6: ...anel The removable battery access cover also has a gasket The front panel is aluminum with durable polycarbonate graphical overlay The lid of the R1L E2A case further serves as a storage area for the...

Страница 7: ...lect the desired resistance range for the resistance under test There are five ranges marked 2 m 20 m 200 m 2 and 20 Note that although the ranges are marked 2 etc the actual reading limit is 1 999 m...

Страница 8: ...t probes HTP 101A and or a pair of Kelvin Probes SKP 8 The probes are color coded a red one for use with the left hand and a white one for use with the right hand Each probe is attached to an eight fo...

Страница 9: ...Page 1 5 10 TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 sales tegam com INSTRUMENT DESCRIPTION Figure 1 Front Panel and Controls...

Страница 10: ...ordered 1 set of Pistol shaped Test Probes HTP 101A and or 1 set of Kelvin Probes SKP 8 1 5 Storage and Shipping Requirements Storage Temperature 40 C to 71 C Relative humidity 0 to 100 non condensing...

Страница 11: ...pen the lid Since the lid is well gasketed it may be difficult to open if there is an appreciable difference between external and internal air pressure Check for the presence of two test probes stored...

Страница 12: ...and install the three D cells in the battery holder When installing the cells rotate them slightly to ensure connection to the battery holder contacts The cells are connected in series for a nominal...

Страница 13: ...d tighten the six captive screws to secure it If the test probes are to be used connect their leads to the corresponding color coded binding post on the R1L E2A front panel as shown in figure 2a and 2...

Страница 14: ...Page 2 4 10 TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 sales tegam com PREPARATION FOR USE AND INSTALLATION Figure 2a HTP 101A Probe Connections...

Страница 15: ...Page 2 5 10 TEGAM WAY GENEVA OHIO 44041 440 466 6100 FAX 440 466 6110 sales tegam com PREPARATION FOR USE AND INSTALLATION Figure 2b SKP 8 Probe Connections...

Страница 16: ...half bright depressing the switch again will turn the backlight on to maximum brightness and depressing the switch a third time will turn the backlight OFF Whenever power to the R1L E2A is turned OFF...

Страница 17: ...len to a value near the end of its useful life LOBAT will be seen on the display The unit will not be damaged by further use but this is a warning that readings may not be accurate especially on the 2...

Страница 18: ...o address the particular service request by you which is assigned to that RMA number Of even greater importance a detailed written description of the problem should be attached to the instrument Many...

Страница 19: ...ssing and repair process RMA Instrument Model Serial Number Company Technical Contact Phone Number Additional Contact Info Repair Instructions Evaluation Calibration Only Repair Only Repair Calibratio...

Страница 20: ...ill recalibrate any product which does not conform to the published accuracy specifications In order to exercise this warranty TEGAM Inc must be notified of the defective product before the expiration...

Страница 21: ...special or consequential damages Purchaser s sole and exclusive remedy in the event any item fails to comply with the foregoing express warranty of TEGAM shall be to return the item to TEGAM shipping...

Отзывы: