Operation

PREPARING TO START THE PUMP

Never run pump
dry. Running pump

without water may cause pump to
overheat, damaging seal and possibly
causing burns to persons handling
pump. Fill pump with water before
starting.

Never run pump
against closed

discharge. To do so can boil water inside
pump, causing hazardous pressure in
unit, risk of explosion and possibly
scalding persons handling pump.

1. Remove the priming plug from the

pump and fill the pump (See Figure
8), fill all piping between the pump
and the well, and make sure that all
piping in the well is full. If you have
also installed a priming tee in the
suction piping, remove the plug
from the tee and fill the suction
piping.

2. Replace all fill plugs. 

3. Power on! Start the pump. If you

don’t have water after 2 or 3

minutes, stop the pump and remove
the fill plugs. Refill the pump and
piping. You may have to repeat this
several times in order to get all the
trapped air out of the piping. A
pump lifting water 25’ may take as
long as 15 minutes to prime.

4. After the pump has built up

pressure in the system and shut off,
check the pressure switch operation
by opening a faucet or two and
running enough water out to bleed
off pressure until the pump starts.
The pump should start when
pressure drops to 30 psi and stop
when pressure reaches 50 psi. Run
the pump through one or two
complete cycles to verify correct
operation. This will also help clean
the system of dirt and scale
dislodged during installation.

Maintenance

Pump and piping need not be
disconnected to repair or replace
motor or seal (See Figure 11).

If motor is replaced, replace the seal
plate O-ring and shaft seal. (Figure 29,

Ref. Nos 5 and 6, Page 15). Keep these
items on hand for future use.

Be sure to prime pump before starting.

NOTE:

Check motor label for

lubrication instructions. The
mechanical shaft seal in the pump is
water lubricated and self-adjusting.

NOTE:

Drain pump when

disconnecting from service or when it
might freeze.

WINTERIZING

PRECHARGE TANK

1. Disconnect pressure switch tube at

pump body and drain pump.

2. Remove priming plug to vent pump;

drain pressure tank and all piping to
a point below frost line.

3. Drain any piping that may be cut off

from system drain due to check
valves in pipe, etc.

STANDARD TANK

1. Follow steps 1, 2, and 3 above.

2. Disconnect air volume control (AVC)

tubing and turn AVC 180° counter-
clockwise. Any water in AVC will
then drain back into tank (See
Figure 9).

Models 3P683D, 3P684D, 2P899A and 3P715B

9

Teel Operating Instructions and Parts Manual

®

E

N
G

L

I

S

H

Fill pump 
and piping 
through 
priming tee.

Figure 8 – Fill Pump

Figure 9 – Winterizing Standard Tank

WARNING

Hazardous voltage!
Can shock, burn, or
cause death.

Disconnect power
before working
on pump or motor.

To winterize,
disconnect AVC
and turn 180°
CCW.

Fill pump
and piping
through
priming tee.

Содержание 2P899A

Страница 1: ...a 6 gallon pre charged tank equal to a fifteen gallon standard tank Used with drilled cased driven point or dug wells or in cisterns or lakes Comes assembled to save on installation Equipped with a 11...

Страница 2: ...ound motor before connecting to power supply Meet United States National Electri cal Code Canadian Electrical Code and local codes for all wiring Follow wiring instructions in this manual when connect...

Страница 3: ...cept as provided below no warranty or affirmation of fact expressed or implied other than as stated in the LIMITED WARRANTY above is made or authorized by Dayton PRODUCT SUITABILITY Many jurisdictions...

Страница 4: ...ould be at least as large as the suction port on the pump include a check valve See Figure 1 Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the pump body and so th...

Страница 5: ...est possible fittings especially elbows in the suction pipe The suction pipe should be at least as large as the suction port on the pump 2 Assemble a foot valve and suction pipe See Figure 3 Make sure...

Страница 6: ...ove the 1 8 NPT pipe plug from the pump Air Volume Control AVC port See Figure 5 Run tubing from the pump s AVC port See Figure 5 to the port on the AVC mounted on the tank See instructions provided w...

Страница 7: ...Manual E N G L I S H Figure 7 Motor wiring connections through Pressure Switch Match motor voltage to line voltage A B L2 L1 A B L2 L1 A B L2 L1 A B L2 L1 230 Volt to 115 Volt Conversion Spade Connect...

Страница 8: ...authority NOTE If you are connecting the motor to a 230 volt circuit using a four conductor cable connect both the neutral white and ground green to the ground terminal The other two wires two black w...

Страница 9: ...Run the pump through one or two complete cycles to verify correct operation This will also help clean the system of dirt and scale dislodged during installation Maintenance Pump and piping need not b...

Страница 10: ...haft flats and unscrew impeller by turning counterclockwise when looking into eye of impeller 5 To reinstall reverse steps 1 through 4 Mount diffuser as shown in Figure 20 6 See directions under Pump...

Страница 11: ...seat correctly after recleaning cavity place a cardboard washer over polished seal face and carefully press into place using a piece of standard 3 4 pipe as a press IMPORTANT Be sure you do not scrat...

Страница 12: ...8 washer pull heat sink into cavity See Figure 22 5 Clean out any surplus Permatex from insert cavity where new seal will be located Figure 23 6 Follow steps 2 through 11 under Installing New Seal PU...

Страница 13: ...nnect power to pump 2 Follow steps 2 through 5 under Testing For Bladder Leakage above 3 Remove nuts from tank cover flange Tap cover flange to break seal and remove 4 Bladder will not come out in one...

Страница 14: ...tire gauge Air pressure should be 2 psi below pump pressure switch cut in setting 3 If the air pressure is more than 2 psi below the cut in setting add air to the tank Use an air compressor or a porta...

Страница 15: ...ed Pipe plug 1 14 1 4 NPT w TFE Barbed elbow 2 15 Switch tube U37 191P 1 16 Plastic gasket J20 18 1 17 Pump ejector body insert N76 29P 1 18 10 16 Hi Lo Capscrew U30 742SS 4 19 45 Nozzle N34P 19 1 20...

Страница 16: ...list Address parts correspondence to Grainger Parts P O Box 3074 1657 Shermer Road Northbrook IL 60065 3074 U S A 1 Tank Assembly Incl Diaphragm Valve Nuts Inlet Flange U231 498 1 2 Inlet Flange Assem...

Страница 17: ...er level in a shallow well operation exceeds 25 ft a deep well pump is needed 3 Ejector or impeller is plugged 3 Clean ejector or impeller see maintenance 4 Check or foot valves stuck in closed 4 Repl...

Страница 18: ...f necessary add air pressure with an air hose Check air valve for leaks using a soapy solution and replace core if necessary Air spurts from 1 Pump is picking up prime 1 As soon as pump picks up prime...

Отзывы: