teel 2P899A Скачать руководство пользователя страница 4

Installation

REPLACING AN OLD PUMP

Hazardous voltage.

Disconnect power

to pump before working on pump or
motor.

1. Drain and remove the old pump.

Check pipe for scale, lime, rust, etc.,
and replace it if necessary.

2. Install the pump in the system. Make

sure that all pipe joints in the suction
pipe are air-tight as well as water
tight. If the suction pipe can suck air,
the pump will not be able to pull
water from the well.

3. Adjust the pump mounting height so

that the plumbing connections do
not put a strain on the pump body.
Support the pipe so that the pump
body does not take the weight of
piping or fittings. 

You have just completed the well
plumbing for your new shallow well jet
pump. Please go to Page 6 for
discharge pipe and tank connections.

WELL POINT (DRIVEN POINT)
INSTALLATION (FIGURE 1)

1. Drive the well, using  “drive

couplings” and a “drive cap”.  “Drive
fittings” are threaded all the way
through and allow the pipe ends to
butt against each other so that the
driving force of the maul is carried by
the pipe and not by the threads. The
ordinary fittings found in hardware
stores are not  threaded all the way
through the fitting and can collapse
under impact.  “Drive fittings” are
also smoother than standard
plumbing fittings, making ground
penetration easier.

2. Mount the pump as close to the well

as possible.

3. Use the fewest possible fittings

(especially elbows) when connecting
the pipe from the well point to the
pump suction port. The suction pipe
should be at least as large as the
suction port on the pump (include a
check valve – See Figure 1). Support
the pipe so that there are no dips or
sags in the pipe, so it doesn’t strain
the pump body, and so that it slopes
slightly upward from the well to the
pump (high spots can cause air
pockets which can air lock the
pump). Seal the suction pipe joints
with teflon tape or a teflon based
pipe joint compound. Joints must be

air- and water-tight. If the suction
pipe can suck air, the pump cannot
pull water from the well. If one well
point does not supply enough water,
consider connecting two or three
well points to one suction pipe.

You have just completed the suction
piping for your new shallow well jet
pump. Please go to Page 6 for
discharge pipe and tank connections

CASED WELL INSTALLATION, 2” OR
LARGER CASING (FIGURE 2)

1. Mount the pump as close to the well

as possible. 

2. Assemble the foot valve, strainer,

and well pipe (See Figure 2). Make
sure that the foot valve works freely.  

4

Teel Operating Instructions and Parts Manual

3P683D, 3P684D, 2P899A and 3P715B

Teel Standard Shallow Well 
Jet Pumps and Systems

®

E

N
G

L

I

S

H

To Household
Water System

Suction Pipe
From Well

Priming
Tee and
Plug

Pump
Priming
Tee and
Plug

Drive
Coupling

Drive
Point

Check
Valve

Not

to

Scale

1861 0795WWG

Install a Line Check Valve 
if horizontal pipe
length is long.

Figure 1 – Driven Point
Installation

Pump
Priming
Tee and
Plug

Suction Pipe
From Well

Not

to

Scale

5-10'

At least

10'

1862 0795WWG

To Household
Water System

Priming
Tee and
Plug

Well
Casing

Foot
Valve

Sanitary
Well Seal

Install a Line Check Valve 
if horizontal pipe
length is long.

Figure 2 – Cased Well Installation

Содержание 2P899A

Страница 1: ...a 6 gallon pre charged tank equal to a fifteen gallon standard tank Used with drilled cased driven point or dug wells or in cisterns or lakes Comes assembled to save on installation Equipped with a 11...

Страница 2: ...ound motor before connecting to power supply Meet United States National Electri cal Code Canadian Electrical Code and local codes for all wiring Follow wiring instructions in this manual when connect...

Страница 3: ...cept as provided below no warranty or affirmation of fact expressed or implied other than as stated in the LIMITED WARRANTY above is made or authorized by Dayton PRODUCT SUITABILITY Many jurisdictions...

Страница 4: ...ould be at least as large as the suction port on the pump include a check valve See Figure 1 Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the pump body and so th...

Страница 5: ...est possible fittings especially elbows in the suction pipe The suction pipe should be at least as large as the suction port on the pump 2 Assemble a foot valve and suction pipe See Figure 3 Make sure...

Страница 6: ...ove the 1 8 NPT pipe plug from the pump Air Volume Control AVC port See Figure 5 Run tubing from the pump s AVC port See Figure 5 to the port on the AVC mounted on the tank See instructions provided w...

Страница 7: ...Manual E N G L I S H Figure 7 Motor wiring connections through Pressure Switch Match motor voltage to line voltage A B L2 L1 A B L2 L1 A B L2 L1 A B L2 L1 230 Volt to 115 Volt Conversion Spade Connect...

Страница 8: ...authority NOTE If you are connecting the motor to a 230 volt circuit using a four conductor cable connect both the neutral white and ground green to the ground terminal The other two wires two black w...

Страница 9: ...Run the pump through one or two complete cycles to verify correct operation This will also help clean the system of dirt and scale dislodged during installation Maintenance Pump and piping need not b...

Страница 10: ...haft flats and unscrew impeller by turning counterclockwise when looking into eye of impeller 5 To reinstall reverse steps 1 through 4 Mount diffuser as shown in Figure 20 6 See directions under Pump...

Страница 11: ...seat correctly after recleaning cavity place a cardboard washer over polished seal face and carefully press into place using a piece of standard 3 4 pipe as a press IMPORTANT Be sure you do not scrat...

Страница 12: ...8 washer pull heat sink into cavity See Figure 22 5 Clean out any surplus Permatex from insert cavity where new seal will be located Figure 23 6 Follow steps 2 through 11 under Installing New Seal PU...

Страница 13: ...nnect power to pump 2 Follow steps 2 through 5 under Testing For Bladder Leakage above 3 Remove nuts from tank cover flange Tap cover flange to break seal and remove 4 Bladder will not come out in one...

Страница 14: ...tire gauge Air pressure should be 2 psi below pump pressure switch cut in setting 3 If the air pressure is more than 2 psi below the cut in setting add air to the tank Use an air compressor or a porta...

Страница 15: ...ed Pipe plug 1 14 1 4 NPT w TFE Barbed elbow 2 15 Switch tube U37 191P 1 16 Plastic gasket J20 18 1 17 Pump ejector body insert N76 29P 1 18 10 16 Hi Lo Capscrew U30 742SS 4 19 45 Nozzle N34P 19 1 20...

Страница 16: ...list Address parts correspondence to Grainger Parts P O Box 3074 1657 Shermer Road Northbrook IL 60065 3074 U S A 1 Tank Assembly Incl Diaphragm Valve Nuts Inlet Flange U231 498 1 2 Inlet Flange Assem...

Страница 17: ...er level in a shallow well operation exceeds 25 ft a deep well pump is needed 3 Ejector or impeller is plugged 3 Clean ejector or impeller see maintenance 4 Check or foot valves stuck in closed 4 Repl...

Страница 18: ...f necessary add air pressure with an air hose Check air valve for leaks using a soapy solution and replace core if necessary Air spurts from 1 Pump is picking up prime 1 As soon as pump picks up prime...